MIC/LINE INPUT is provided to connect a local microphone in each zone. This is a 3-pin Phoenixtype connector where pin 1 is ground, pin 2 is signal high (+), and pin 3 is signal low (-). AMBIENT MIC is a 3-pin Phoenix-type connector used to connect the optional MT-3100 ambient microphone, one for each zone. This microphone is used to detect the ambient noise level in the room. The microprocessor uses this information to adjust the paging mic level above the ambient noise. The ambient mic also provides an input for the optional DSP card when it is installed. EQ is a 3-band equalizer with a sweepable midrange that only affects Inputs 1-4. LOW is a shelving filter that provides 15 dB of boost and cut below 80Hz. MID is a peaking filter that provides 15 dB of boost and cut at the selected frequency between 250Hz and 8kHz. HIGH is a shelving filter that provides 15 dB of boost and cut above 12kHz. AMP ADDRESS is used to assign a unique address to each amplifier, as well as to enable or disable features. Switches 1-5 provide 32 separate addresses, switch 6 determines Master/Slave status, switch 7 enables Input 4 Priority, and switch 8 enables the optional ambient mic. Any two amplifiers assigned to the same address can be controlled by a single remote control when connected together via the RS485 ports. RS485 is a 3-pin Phoenix-type connector in each zone that provides an interface for the SPLinker Sound Palette Control PC application software for centralized computer control of up to 32 zones, as well as communication between SP2400s. The RS485 interface is internally connected between the two amplifiers, so if both amplifiers are assigned the same zone with the AMP ADDRESS switch, the front panel controls and remote controls operate both sides, ideal for stereo operation. REMOTE is a 3-pin Phoenix-type connector for the optional wired remote control (SP-41R), which provides Input Select and Master Volume control. EXPANSION IN/OUT consists of two parallel 25pin D-Sub connectors for connecting multiple SP2400s together in a serial fashion. Any of the four program sources from any SP2400 can be used as the source for any of the zones in the system by assigning it to the expansion bus with the internal Bus Assign switches. This is a balanced bus for the four stereo input sources. In addition, the paging mic and paging control signal are also provided on the EXPANSION bus. LOCAL/REMOTE is a set of eight DIP switches used to select the input source for the channel. Each program input has two switches, one to select the left signal source (odd-numbered switches) and one to select the right signal source (evennumbered switches). Move the switches up to select the local program source, and down to select the remote (external) program source from the EXPANSION bus. STEREO/MONO switches configure each input source for either stereo or mono operation. If the SP2400 is being used in a stereo configuration, leave the switches up. If it's being used in a zone configuration, move the switches down to combine the left and right channels for mono operation. PRE OUT is an unbalanced RCA jack that provides a line-level signal from the preamplifier stage of the SP2400. This provides a method for inserting an external signal processor into the signal chain prior to the amplifier stage. The U-shaped jumper wire should remain installed between the PRE OUT and AMP IN jacks for normal operation. AMP IN is an unbalanced RCA jack that accepts a line-level signal. See PRE OUT above. ZONE A/ZONE B OUTPUTS are 2-pin Phoenixtype connectors that provide speaker-level signals. The SP2400 is shipped with the outputs configured for 70-volt operation in U.S. versions, and 100-volt operation in European versions. Internal jumpers are provided to configure the amplifier for 8 ohm systems as well. See page 14 for more information. Connect the supplied AC linecord to the IEC AC Socket. The AC line fuse is contained in the socket, behind the cover located at the bottom of the socket. Use replacement fuses only as indicated on the rear panel. 115V 60Hz FUSE 115/ T8A 220 WATTS 230V 50Hz FUSE 230/ T4A 220 WATTS SP2400 MUSIC CONTROLLER SERIAL NUMBER MANUFACTURING DATE DIRECT L THE FOLLOWING ARE TRADEMARKS OR REGISTERED TRADEMARKS OF MACKIE DESIGNS INC "MACKIE.","MACKIE INDUSTRIAL", AND THE "RUNNING MAN" FIGURE. COPYRIGHT ©2000 ALL RIGHTS RESERVED LOCAL 1234 STEREO R CAUTION: TO REDUCE THE RISK OF FIRE REPLACE WITH SAME TYPE FUSE AND RATING ZONE B STEREO RIGHT OUTPUT SUITABLE FOR CLASS 2 WIRING 100/ 70V/8 + - AGB I 123 0 12345678 AMP ADDRESS RS485 REMOTE EXPANSION IN EXPANSION OUT 12345678 1234 1234 REMOTE MONO OUTPUT 1 CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE DESIGNS INC. • WOODINVILLE • WA • MADE IN USA • FABRIQUE AU USA MIC/LINE INPUT B PAGING PROGRAM EQ ZONE A GAIN G+- LOW U PHANTOM HIGH U GAIN +40dB G+- MIC VOX PRE OUT LOW 80Hz U STEREO LEFT MID FREQ HIGH 12k OUTPUT SUITABLE U 1K U FOR CLASS 2 WIRING 100/ 70V/8 + - 400 3K AGB I AMBIENT MIC 1234 + -12 +12 -12 +12 - + AMP IN -15 +15 -15 +15 250 8k -15 +15 0 12345678 AMP ADDRESS RS485 PROGRAM INPUTS PRIORITY 2 3 4 PAGING MIC GROUND ALL CALL PAR ALLEL INPUTS G+- ZONE A ZONE B PHANTOM GAIN +40dB CONTROL GAIN LOW U HIGH U 1234 ON - + -12 +12 -12 +12 MIC/LINE INPUT A PAGING 1 2 3 G+- GAIN LOW U PHANTOM HIGH U GAIN +40dB G+- MIC VOX PRE OUT REMOTE AMBIENT MIC 1234 + -12 +12 -12 +12 - + AMP IN PROGRAM EQ LOW 80Hz MID U U FREQ 1K HIGH 12k U 400 3K -15 +15 -15 +15 250 8k -15 +15 SP2400 - 5
![](/manual_guide/products/mackie-sp2400-instruction-manual-aed3f11/5.png)