Maintenance

Page 7 highlights

1 Nails 007303 1. Contact top 2. Contact arm With tool disconnected, make daily inspection to assure free movement of the contact element and trigger. Do not use tool if the contact element or trigger sticks or binds. 007195 2 004310 When the tool is not to be used for an extended period of time, lubricate the tool using pneumatic tool oil and store the tool in a safe place. Avoid exposure to direct sunlight and/or humid or hot environment. 007193 Handle nail coils and their box carefully. If the nail coils have been handled roughly, they may be out of shape or their connector breaks, causing poor nail feed. Avoid storing nails in a very humid or hot place or place exposed to direct sunlight. 004311 007194 MAINTENANCE CAUTION: • Always disconnect the air hose from the tool before attempting to perform inspection or maintenance. Maintenance of nailer Always check the tool for its overall condition and loose screws before operation. Tighten as required. 007192 Maintenance of compressor, air set and air hose 004317 1. Drain cock 1 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

7
Nails
Handle nail coils and their box carefully. If the nail coils
have been handled roughly, they may be out of shape or
their connector breaks, causing poor nail feed.
Avoid storing nails in a very humid or hot place or place
exposed to direct sunlight.
MAINTENANCE
CAUTION:
Always disconnect the air hose from the tool before
attempting to perform inspection or maintenance.
Maintenance of nailer
Always check the tool for its overall condition and loose
screws before operation. Tighten as required.
With tool disconnected, make daily inspection to assure
free movement of the contact element and trigger. Do not
use tool if the contact element or trigger sticks or binds.
When the tool is not to be used for an extended period of
time, lubricate the tool using pneumatic tool oil and store
the tool in a safe place. Avoid exposure to direct sunlight
and/or humid or hot environment.
Maintenance of compressor, air set and air
hose
1. Contact top
2. Contact arm
1
2
007303
004310
004311
007192
1. Drain cock
007195
007193
007194
1
004317