Water Piping, T&P Valve and Pipe Insulation
![]() |
View all Maytag HRE2940T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Instructions for Installation (cont'd) Water Piping 2. Look at the top cover of the water heater. The cold water inlet is marked cold. Connect the cold water pipe to the cold water inlet of the water heater. * WARNING HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve, should be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufacturers instructions for installation of the valves. Before changing the factory setting on the thermostat, read the "Temperature Regulation" section in this manual. *See illustration on page 9 for mixing valve usage. NOTE: Your water heater is super insulated to minimize heat loss from the tank. Further reduction in heat loss can be accomplished by insulating the hot water lines from the water heater. HOT OUTLET TO HOUSE SHUT-OFF VALVE COLD INLET WATER LINE THREADED TO SWEAT COUPLING THREADED TO SWEAT COUPLING 3/4″ THREADED NIPPLE HOT COLD 3/4″ THREADED NIPPLE TEMPERATUREPRESSURE RELIEF VALVE If a water heater is installed in a closed water supply system; such as one having a back-flow preventer, check valve, water meter with a check valve, etc. in the cold water supply; means shall be provided to control thermal expansion. Contact the local utility or call Maytag Customer Service at 1-800-788-8899 for an authorized servicer on how to control this situation. DISCHARGE PIPE (Do not cap or plug) NOTE: To protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that di-electric unions or couplings be installed on this water heater when connected to copper pipe. 6″ AIR GAP NOTE: The secondary anode rod/hot outlet nipple and the cold inlet nipple are packaged separately with the water heater. The above parts must be installed in the appropriate HOT and COLD water connection locations. FLOOR DRAIN T&P Valve and Pipe Insulation (on Selected Models) The illustration shows the attachment of the water piping to the water heater. The water heater is equipped with 3⁄4 inch water connections. NOTE: If using copper tubing, solder tubing to an adapter before attaching the adaptor to the cold water inlet connection. Do not solder the cold water supply line directly to the cold water inlet. It will harm the dip tube and damage the tank. 1. Look at the top cover of the water heater. The water outlet is marked hot. Connect the hot water pipe to the hot water outlet of the water heater. Remove insulation for T&P Valve and pipe connections from carton. Fit pipe insulation over the incoming cold water line and the hot water line. Make sure that the insulation is against the top cover of the heater. Fit T&P Valve insulation over valve. Make sure that the insulation does not interfere with the lever of the T&P valve. Secure all insulation using tape. 11
![](/manual_guide/products/maytag-hre2940t-user-guide-ec86bd2/11.png)