Maytag HRE2940T User Guide - Page 18

Installation Checklist

Page 18 highlights

Instructions for Installation (cont'd) Installation Checklist 1. Whether or not the element conversion is made, the model HOT rating plate must be marked. Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower access panel. COLD 2. Is the fuse or circuit breaker size correct as shown in the chart in the "Product Specifications" section? 3. Are the wires from the circuit breaker or fuse service to the water heater's junction box on the correct wire size (gauge) as shown in the chart in the "Product Specifications" section? CONDUIT HOT COLD TEMPERATUREPRESSURE RELIEF VALVE 4. Is the new temperature-pressure relief valve properly installed, and piped to an adequate drain? See "Temperature-Pressure Relief Valve" in the "Instructions for Installation" section. 5. Is the water heater completely filled with water? See "Filling the Water Heater" instructions in the "Instructions for Installation" section. DISCHARGE PIPE (Do not cap or plug) 6. Will a water leak damage anything? See "Locating the New Water Heater" in the "Instructions for Installation" section. 7. Are the cold and hot water lines connected to the water heater correctly? See "Water Piping" instructions in the "Instructions for Installation" section. 6″ AIR GAP FLOOR DRAIN 8. Is there adequate clearance for maintenance around the water heater? 9. Do you need to call your electric company to check your wiring? MODEL RATING PLATE 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

MODEL RATING PLATE
FLOOR DRAIN
DISCHARGE PIPE
(Do not cap or
plug)
6
AIR GAP
HOT
18
COLD
TEMPERATURE-
PRESSURE
RELIEF VALVE
CONDUIT
HOT
COLD
Installation Checklist
1.
Whether or not the element conversion is made, the model
rating plate must be marked. Using a hard point ink pen,
check the appropriate block within the model rating plate,
which is located adjacent to the lower access panel.
2.
Is the fuse or circuit breaker size correct as shown in the
chart in the “Product Specifications” section?
3.
Are the wires from the circuit breaker or fuse service to the
water heater’s junction box on the correct wire size (gauge) as
shown in the chart in the “Product Specifications” section?
4.
Is the new temperature-pressure relief valve properly
installed, and piped to an adequate drain? See
“Temperature-Pressure Relief Valve” in the “Instructions
for Installation” section.
5.
Is the water heater completely filled with water? See
“Filling the Water Heater” instructions in the “Instructions
for Installation” section.
6.
Will a water leak damage anything? See “Locating the
New Water Heater” in the “Instructions for Installation”
section.
7.
Are the cold and hot water lines connected to the water
heater correctly? See “Water Piping” instructions
in the
“Instructions for Installation” section.
8.
Is there adequate clearance for maintenance around the
water heater?
9.
Do you need to call your electric company to check your
wiring?