To Avoid The Possibility Of Water Damage: • Have Water Faucets Easily Accessible • Turn Off Faucets When Washer Is Not In Use. DRAIN FACILITY Recommended height of the standpipe is 18". The drain hose must be routed through the drain hose clip to the standpipe. Standpipe must be large enough to accept the outside diameter of the drain hose. The drain hose is attached at the factory. FLOORING For best performance the washer must be installed on a solidly constructed floor. Wood floors may need to be reinforced to minimize vibration and/or unbalanced load situations. Carpeting and soft tile surfaces are contributing factors in vibration and/or tendency for a washer to move slightly during the spin cycle. Never install the washer on a platform or weakly supported structure. LOCATION CONSIDERATIONS It is recommended the washer never be installed in areas where water may freeze since the washer will always maintain some water in the water valve, pump and hose areas. This can cause damage to belts, pump, hoses and other components. Operating temperature should be above 60°F. ALCOVE OR CLOSET INSTALLATION MINIMUM CLEARANCES FOR CLOSET AND ALCOVE INSTALLATIONS: Sides - 0 in / 0 mm Rear - 01 in / 250 mm Top - 02 in / 501 mm Closet Front - 0 in / 0 mm The closet front must have a total unobstructed air opening of 72 in2. / 465 cm2 minimum, if both washer and dryer are installed together. A louvered door with equivalent air opening is acceptable. Washer alone does not require specific air opening. UNDERCOUNTER INSTALLATION MINIMUM CLEARANCES FOR UNDERCOUNTER INSTALLATIONS: Sides - 0 in / 0 mm Rear - 0 in / 0 mm Top - 0 in / 0 mm Front - 0 in / 0 mm 26" min. 23 1/2" 4 33 1/4" - 34 1/8"

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

To Avoid The Possibility Of Water Damage:
Have Water Faucets Easily Accessible
Turn Off Faucets When Washer Is Not In Use.
DRAIN FACILITY
Recommended height of the standpipe is 18
. The drain hose must be routed through the drain hose clip to
the standpipe. Standpipe must be large enough to accept the outside diameter of the drain hose. The drain
hose is attached at the factory.
FLOORING
For best performance the washer must be installed on a solidly constructed floor. Wood floors may need to
be reinforced to minimize vibration and/or unbalanced load situations. Carpeting and soft tile surfaces are
contributing factors in vibration and/or tendency for a washer to move slightly during the spin cycle. Never
install the washer on a platform or weakly supported structure.
LOCATION CONSIDERATIONS
It is recommended the washer never be installed in areas where water may freeze since the washer will
always maintain some water in the water valve, pump and hose areas. This can cause damage to belts,
pump, hoses and other components. Operating temperature should be above 60
°
F.
ALCOVE OR CLOSET INSTALLATION
MINIMUM CLEARANCES FOR CLOSET AND ALCOVE INSTALLATIONS:
Sides
0 in / 0 mm
Rear
1 in / 25 mm
Top
2 in / 51 mm
Closet Front
0 in / 0 mm
The closet front must have a total unobstructed air opening of 72 in
2
. / 465 cm
2
minimum, if both washer and
dryer are installed together. A louvered door with equivalent air opening is acceptable. Washer alone does
not require specific air opening.
UNDERCOUNTER INSTALLATION
MINIMUM CLEARANCES FOR UNDERCOUNTER INSTALLATIONS:
Sides
0 in / 0 mm
Rear
0 in / 0 mm
Top
0 in / 0 mm
Front
0 in / 0 mm
0
0
0
0
33 1/4" - 34 1/8"
4
26” min.
23 1/2”