Maytag MDB7609AWB Installation Instructions - Page 12
Power Supply - ratings
UPC - 883049182827
View all Maytag MDB7609AWB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Instalal ULlistedorCSAapprovedstrainreliefM. akesure screwheadasrefacingto theleftwhentighteningconduit nut.Thestrainreliefmaybeprovidedwiththepower supplycordkit. Electrical Shock Hazard Electrically ground dishwasher. Connect ground wire to green ground connector in terminal box. Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock. connection will you use? [ __ Power Supply Cord: Follow Option A instructions Direct Wire: Follow Option B instructions Make Power Supply Cord Connection Option A, Power Supply Cord: II I _ t!l _}--Ground i///,G;Yit X wire /tW_s///..._ . ? _---w,re _ash ) Ground Remove the green grounding screw and place through the ring terminal of the green ground wire. Reattach and tighten the green screw. Route cord so that it does not touch dishwasher motor to lower part of dishwasher tub. Pull cord through strain relief in terminal bow. Take notice when installing or removing the dishwasher in order to reduce the chance of damaging the power supply cord. Select UL listed or CSA approved twist-on wire connectors (included with power supply cord kit) rated to connect your household wiring to 16-gauge dishwasher wiring. 12 NOTE: Do not pre-twist stranded wire. Twist on wire connector. Gently tug on wires to be sure both are secured. Connect wires black to black and white to white, using UL listed or CSA approved twist-on wire connectors (included with power supply cord kit).