Maytag MDB7609AWB Installation Instructions - Page 13
Determine - black
UPC - 883049182827
View all Maytag MDB7609AWB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Wiring configuration Determine Cabinet Opening black _ ground W!re _ black ground connector If needed, see website for animated representation of this step. Visit www.maytag.eom under FAQ tab. J Power cord - Secure cord on conduit connector 0 Measure height of cabinet opening from underside of countertop to floor where dishwasher will be installed (you will need to measure the lowest point on the underside of the countertop and the highest point on the floor). Refer to "Dishwasher Height Adjustment Chart" for wheel position and the number of turns needed. Tighten strain relief screws to secure cord. ) Cabinet " Opening height 337i8 (860 I Wheel position remo_e 34 (86 4cm) ! 1 34 1/4, (87 cm). 2 . 34 1/2" (87,6 cm) 3 Number of turns on front leg A!! the Way Up . 10 I 5 .... m : 0 NOTE: If the minimum cabinet opening height is less than 34"(86.4 cm), the rear wheels can be removed for additional clearance. This will allow the dishwasher to fit into a 33 7/8" (86 cm) high cabinet opening, but the dishwasher will be more difficult to move. (Measurements are approximate. Wheels and legs are preset at the factory for 34 1/2" [87.6 cm].) Place wires inside terminal box. Insert tabs on left side of cover. Make sure wires are tucked inside box. Close cover ensuring wires are not pinched. Use 1/4" nut driver and previously removed screw to secure cover. NOTE: Do not plug into outlet until instructed to do so. ) Turn both leveler legs to the same height. Put wheels in the required position determined from "Dishwasher Height Adjustment Chart." 13