Maytag MEDB755DW Installation Guide - Page 11

Make Electrical Connection - U.s.a. Only Effectuer Le, Raccordement Électrique - États-unis

Page 11 highlights

MAKE ELECTRICAL CONNECTION - U.S.A. ONLY (EFFECTUER LE RACCORDEMENT ÉLECTRIQUE - ÉTATS-UNIS SEULEMENT) Power Supply Cord Direct Wire ELECTRICAL CONNECTION OPTIONS 1. Choose electrical connection type Power supply cord 4-wire receptacle (NEMA Type 14-30R): Go to steps 1-2 on page 12 for power supply cord strain relief: then steps 3-6 for 4-wire Power Supply Cord Connection section. Then, go to Venting Requirements. Power supply cord 3-wire receptacle (NEMA Type 10-30R): Go to steps 1-2 on page 13 for power supply cord strain relief: then steps 3-5 for 3-wire Power Supply Cord Connection section. Then go to Venting Requirements. 4-wire direct connection: Go to steps 1-2 on page 14 for direct wire strain relief: then steps 3-8 for 4-wire Direct Wire Connection section. Then go to Venting Requirements. 3-wire direct connection: Go to steps 1-2 on page 15 for direct wire strain relief: then steps 3-7 for 3-wire Direct Wire Connection section. Then go to Venting Requirements. NOTE: If local codes do not permit connection of a cabinet-ground conductor to neutral wire, go to "Optional 3-wire Connection" section. This connection may be used with either a power supply cord or a direct wire connection. 2. Remove terminal block cover BE C F D A Before you start, disconnect power. Remove hold-down screw (D) and terminal block cover (A). A. Terminal block cover B. External ground conductor screw C. Center terminal block screw D. Hold-down screw E. Neutral ground wire F. Hole below terminal block cover 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

11
MAKE ELECTRICAL CONNECTION - U.S.A. ONLY (EFFECTUER LE
RACCORDEMENT ÉLECTRIQUE – ÉTATS-UNIS SEULEMENT)
Power Supply Cord
ELECTRICAL CONNECTION OPTIONS
1.
Choose electrical connection type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to steps 1-2
on page 12 for power supply cord strain
relief: then steps 3-6 for 4-wire Power
Supply Cord Connection section. Then,
go to Venting Requirements.
3-wire direct connection:
Go to steps
1-2 on page 15 for direct wire strain relief:
then steps 3-7 for 3-wire Direct Wire
Connection section. Then go to Venting
Requirements.
4-wire direct connection:
Go to steps
1-2 on page 14 for direct wire strain relief:
then steps 3-8 for 4-wire Direct Wire
Connection section. Then go to Venting
Requirements.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to steps 1-2
on page 13 for power supply cord strain
relief: then steps 3-5 for 3-wire Power
Supply Cord Connection section. Then
go to Venting Requirements.
NOTE:
If local codes do not permit connection of a
cabinet-ground conductor to neutral wire, go to “Optional
3-wire Connection” section. This connection may be
used with either a power supply cord or a direct wire
connection.
Direct Wire
A
B
C
C
E
F
D
2.
Remove terminal block cover
Before you start, disconnect power. Remove hold-down
screw (D) and terminal block cover (A).
A. Terminal block cover
B. External ground conductor screw
C. Center terminal block screw
D. Hold-down screw
E. Neutral ground wire
F. Hole below terminal block cover