Installation Clearances The location must be large enough to allow the dryer door to open fully. Dryer Dimensions 43 ³⁄₈" (110 cm) 15¼" (38.74cm) 43³⁄₈" (110 cm) 22 ¾" (57.8 cm) *26" (66 cm) 29" (73.66 cm) A *27 ¾" (70.5 cm) 29" (73.66 cm) B 43 ³⁄₈" (110 cm) 22 ¾" (57.8cm) 43³⁄₈" (110 cm) 13 ¾" (34.9 cm) *27 ¾" (70.5 cm) 29" (73.66 cm) C *27 ¾" (70.5 cm) 29" (73.66 cm) D A. Small opening side-swing door B. Large opening side-swing door C. Wide opening side-swing door D. Wide opening hamper door *Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See "Venting Requirements." Installation spacing for recessed area or closet installation The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons: ■ Additional spacing should be considered for ease of installation and servicing. ■ Additional clearances might be required for wall, door and floor moldings. ■ Additional spacing should be considered on all sides of the dryer to reduce noise transfer. ■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. ■ Companion appliance spacing should also be considered. 18"* (45.7 cm) 14" max.* (35.6cm) 48 in. 2 * (310 cm2) 3"* (7.6 cm) 1" (2.5 cm) 29" (73.66 cm) A 24 in.2 * (155 cm2) 1" 1"* 27¾" 5"* (2.5 cm) (2.5 cm) (70.5 cm) (12.7 cm) B C A. Recessed area B. Side view - closet or confined area C. Closet door with vents 3"* (7.6 cm) *Required spacing Mobile Home - Additional Installation Requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or the Canadian Manufactured Home Standard, CAN/CSA-Z240 MH. Mobile home installations require: ■ Metal exhaust system hardware, which is available for purchase from your dealer. ■ Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening. Electrical Requirements - U.S.A. It is your responsibility ■ To contact a qualified electrical installer. ■ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances. The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations. A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269. ■ To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit. ■ Do not use an extension cord. ■ If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

3
Installation Clearances
The location must be large enough to allow the dryer door to open
fully.
Dryer Dimensions
*Most installations require a minimum 5" (12.7 cm) clearance
behind the dryer for the exhaust vent with elbow. See “Venting
Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this
dryer. This dryer has been tested for spacing of 0" (0 cm)
clearance on the sides and rear. Recommended spacing should
be considered for the following reasons:
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing should be considered on all sides of the
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
*Required spacing
Mobile Home - Additional Installation Requirements
This dryer is suitable for mobile home installations.
The installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction and
Safety, Title 24, HUD Part 280) or the Canadian Manufactured
Home Standard, CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for
purchase from your dealer.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
Electrical Requirements - U.S.A.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electric Code requires a 4-wire supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt
electrical supply, if specified on the serial/rating plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended. Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A. Small opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
43
³⁄₈
"
(110cm)
*26"
(66cm)
29"
(73.66cm)
A
15¼"
(38.74cm)
43
³⁄₈
"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
B
22¾"
(57.8cm)
43
³⁄₈
"
(110cm)
13¾"
(34.9cm)
*27¾"
(70.5cm)
29"
(73.66cm)
D
43
³⁄₈
"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
C
22¾"
(57.8cm)
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
A
B
C
18"*
(45.7 cm)
1"
(2.5 cm)
29"
(73.66 cm)
1"
(2.5 cm)
1"*
(2.5 cm)
14" max.*
(35.6
cm)
27¾"
(70.5 cm)
5"*
(12.7 cm)
48 in.
(310 cm
)
2
*
2
24 in.
(155 cm
)
2
*
2
3"*
(7.6 cm)
3"*
(7.6 cm)