Maytag MEDP576K Installation Instructions - Page 10

Wire Power Supply Cord Connection

Page 10 highlights

4-Wire Power Supply Cord Connection IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections. 3. Connect ground wire 4-wire receptacle (NEMA type 14-30R) 4-prong plug Spade terminals with upturned ends Ring terminals 1. Prepare to connect neutral ground wire and neutral wire E B A Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A). 2. C onnect neutral ground wire and neutral wire A F Connect ground wire (F) (green or bare) of power supply cord to external ground conductor screw (A). Tighten screw. 4. C onnect remaining wires Connect remaining wires to outer terminal block screws. Tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to Venting Requirements. 3-Wire Power Supply Cord Connection IMPORTANT: Use where local codes permit connecting cabinet-ground conductor to neutral wire. 3-wire receptacle (NEMA type 10-30R) 3-prong plug B E C Connect neutral ground wire (E) and neutral wire (white or center) (C) of power supply cord under center terminal block screw (B). Tighten screw. 10 Spade terminals with upturned ends Ring terminals

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

10
4-Wire Power Supply Cord Connection
IMPORTANT:
A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
2.
Connect neutral ground wire and
neutral wire
Connect neutral ground wire (E) and neutral wire (white or
center) (C) of power supply cord under center terminal block
screw (B). Tighten screw.
4-wire receptacle
(NEMA type 14-30R)
Spade terminals
with upturned ends
4-prong plug
Ring terminals
3.
Connect ground wire
Connect ground wire (F) (green or bare) of power supply cord
to external ground conductor screw (A). Tighten screw.
4.
Connect remaining wires
Connect remaining wires to outer terminal block screws.
Tighten screws. Finally, reinsert tab of terminal block cover into
slot of dryer rear panel. Secure cover with hold-down screw.
Now, go to Venting Requirements.
3-Wire Power Supply Cord Connection
IMPORTANT:
Use where local codes permit connecting
cabinet-ground conductor to neutral wire
.
3-wire receptacle
(NEMA type 10-30R)
Spade terminals
with upturned ends
3-prong plug
Ring terminals
1.
Prepare to connect neutral ground
wire and neutral wire
E
B
A
B
E
C
A
F