Maytag MEDP576K Installation Instructions - Page 13

Optional 3-Wire Connection

Page 13 highlights

2. R emove center screw B Remove center terminal block screw (B). 3. C onnect neutral wire B E Place hooked end of neutral wire (white or center) (C) of direct wire cable under center terminal block screw (B). Squeeze hooked end together. Tighten screw. 4. C onnect remaining wires Optional 3-Wire Connection IMPORTANT: You must verify with a qualified electrician that this grounding method is acceptable before connecting. 1. Prepare to connect neutral ground wire and neutral wire E B A Remove center terminal block screw (B). Remove neutral ground wire (E) from external ground conductor screw (A). 2. Connect neutral ground wire and neutral wire B C E Connect neutral ground wire (E) and neutral wire (white or center wire) (C) of power supply cord or cable under center terminal block screw (B). Tighten screw. 3. Connect remaining wires Place hooked ends of remaining direct wire cable wires under outer terminal block screws (hooks facing right). Squeeze hooked ends together and tighten screws. Finally, reinsert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw. Now, go to "Venting Requirements." Place hooked ends of remaining wires under outer terminal block screws (hooks facing right). Tighten screws. 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

13
2.
Remove center screw
Remove center terminal block screw (B).
3.
Connect neutral wire
Place hooked end of neutral wire (white or
center) (C) of direct wire cable under center
terminal block screw (B). Squeeze hooked end
together. Tighten screw.
4.
Connect remaining wires
Place hooked ends of remaining direct wire cable wires under
outer terminal block screws (hooks facing right). Squeeze
hooked ends together and tighten screws. Finally, reinsert tab
of terminal block cover into slot of dryer rear panel. Secure
cover with hold-down screw.
Now, go to “Venting Requirements.”
Optional 3-Wire Connection
IMPORTANT:
You must verify with a qualified
electrician that this
grounding method is acceptable before connecting.
1.
Prepare to connect neutral ground
wire and neutral wire
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
2.
Connect neutral ground wire and
neutral wire
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
3.
Connect remaining wires
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
B
B
E
E
B
A
B
C
E