Maytag MGDE300VF Use and Care Guide - Page 10

Fire Hazard - reviews

Page 10 highlights

Burner input requirements Elevations above 10,000 ft (3,048 m): • When installed above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation. Gas supply pressure testing • The dryer must be disconnected at pressures greater than 1/2psi. from the gas supply piping system during pressure testing Dryer gas pipe The gas pipe that comes out through the rear of your dryer has a sA" male pipe thread. .61A,, (15.9 crn) A. _" NPT gas supply line B. s/s" NPT dryer pipe *NOTE: If the dryer is mounted on a pedestal, the gas pipe height must be an additional 10" (25.4 cm) or 15.5" (39.4 cm) from the floor, depending on the pedestal modem. For a garage installation, the gas pipe height must be an additional 18" (46 cm) from the floor. _ _ 4 _=4,_6, Fire Hazard Use a heavy metal vent. Do not use a plastic vent. Do not use a metal foil vent. Failure to follow these instructions can result in death or fire. If using an existing vent system Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint. Replace any plastic or metal foil vent with rigid or flexible heavy metal vent. Review vent system chart Modify existing vent system if necessary to achieve the best drying performance. If this is a new vent system Vent material • Use a heavy metal vent. 19o not use plastic or metal foil vent. • 4" (10.2 cm) heavy metal exhaust vent and clamps must be used. WARN I NG: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. IMPORTANT: Observe all governing codes and ordinances. The dryer exhaust must not be connected into any gas vent, chimney, concealed space of a building. wall, ceiling or a 4" ( 10.2 cm) heavy metal exhaust vent Vent products can be purchased from your dealer or by calling Maytag Services. For more information, see the "Assistance or Service" section. |0

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Burner
input
requirements
Elevations
above
10,000
ft (3,048
m):
When
installed
above
10,000
ft (3,048
m) a 4%
reduction
of the burner
Btu
rating
shown
on
the
model/serial
number
plate
is required
for each
1,000
ft (305
m) increase
in
elevation.
Gas
supply
pressure
testing
The dryer
must
be disconnected
from
the gas supply
piping
system
during
pressure
testing
at pressures
greater
than
1/2psi.
Dryer
gas pipe
The gas pipe that comes out through the rear of your dryer has a sA" male pipe thread.
.61A,,
(15.9
crn)
A.
_"
NPT gas supply line
B.
s/s"
NPT dryer pipe
*NOTE:
If the
dryer
is mounted
on a pedestal,
the
gas pipe
height
must
be an additional
10"
(25.4
cm)
or 15.5"
(39.4
cm) from
the floor,
depending
on the
pedestal
modem. For a garage
installation,
the
gas pipe
height
must
be an additional
18" (46 cm)
from
the floor.
_
_
_
,_ _, _
....
,4
_=4,_6,
Fire Hazard
Use a heavy
metal
vent.
Do
not
use a plastic
vent.
Do not
use a metal
foil
vent.
Failure
to follow
these
instructions
can result
in
death
or fire.
WARN
I
NG:
To reduce
the
risk
of fire,
this
dryer
MUST
BE EXHAUSTED
OUTDOORS.
IMPORTANT:
Observe
all governing
codes
and
ordinances.
The dryer
exhaust
must
not be connected
into
any gas vent,
chimney,
wall,
ceiling
or a
concealed
space
of a building.
If using
an
existing vent system
Clean
lint
from
the entire
length
of the
system
and
make
sure exhaust
hood
is not plugged
with
lint.
Replace
any plastic
or metal
foil
vent
with
rigid
or flexible
heavy
metal
vent.
Review
vent
system
chart
Modify
existing
vent
system
if necessary
to achieve
the
best
drying
performance.
If this
is a
new vent system
Vent
material
Use a heavy
metal
vent.
19o not
use plastic
or metal
foil
vent.
4" (10.2
cm)
heavy
metal
exhaust
vent
and
clamps
must be
used.
4" ( 10.2 cm) heavy metal exhaust vent
Vent products
can
be purchased
from
your
dealer
or by calling
Maytag
Services.
For more
information,
see the
"Assistance
or Service"
section.
|0