Dryer Dimensions Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer. Place dryer at least 18 inches (46 cm) above the floor for a garage installation. Failure to do so can result in death, explosion, or fire. You will need • A location that allows for proper exhaust installation. A gas dryer must be exhausted to the outdoors. See "Venting Requirements." A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See "Electrical Requirements." A sturdy floor to support the total dryer weight of 200 Ibs (90.7 kg). The combined weight of a companion appliance should also be considered. A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. If slope is greater than 1" (2.5 cm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly, and automatic sensor cycles may not operate correctly if dryer is not [eve[. • For a garage installation, you will need to place the dryer at least 18" (46 cm) above the floor. If using a pedestal, you will need 18" (46 cm) to the bottom of the dryer. Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times. The dryer must not be installed or stored in an area where it will be exposed to water and/or weather. Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector. NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer. Installation clearances The location must be large enough to allow the dryer door to open fully. 38" (96.52 cm) *Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See "Venting Requirements." Installation spacing for recessed area or closet installation The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons: • Additional spacing should be considered for ease of installation and servicing. • Additional clearances might be required for wall, door and floor moldings. • Additional spacing should be considered on all sides of the dryer to reduce noise transfer. • For closet installation, with a doo_; minimum ventilation openings in the top and bottom of the door are required. I.ouvered doors with equivalent ventilation openings are acceptable. • Companion appliance spacing should also be considered. Custom undercounter installation - Dryer only *Required spacing 1"* ---_ I-_---27"--_11_- 1"* (2.5cm) (68.6cm) (2.5cm)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Dryer
Dimensions
Explosion
Hazard
Keep flammable
materials
and
vapors,
such
as
gasoline,
away from
dryer.
Place
dryer
at
least
18
inches
(46 cm) above
the floor
for a garage
installation.
Failure
to do so can result
in
death, explosion,
or fire.
You
will
need
A location
that
allows
for proper
exhaust
installation.
A gas dryer
must be exhausted
to
the
outdoors.
See "Venting
Requirements."
A grounded
electrical
outlet
located
within
2 ft (61 cm)
of either
side
of the
dryer.
See
"Electrical
Requirements."
A sturdy
floor
to support
the total
dryer
weight
of 200
Ibs (90.7
kg). The combined
weight
of
a companion
appliance
should
also
be considered.
A level
floor
with
a maximum
slope
of
1" (2.5 cm)
under
entire
dryer.
If slope
is greater
than
1" (2.5 cm),
install
Extended
Dryer
Feet Kit, Part Number
279810.
Clothes
may not
tumble
properly,
and
automatic
sensor
cycles
may
not operate
correctly
if dryer
is not
[eve[.
For a garage
installation,
you
will
need to
place
the
dryer
at least
18" (46 cm)
above
the
floor.
If using
a pedestal,
you
will
need
18" (46 cm)
to the bottom
of the
dryer.
Do
not operate
your
dryer
at temperatures
below
45°F
(7°C).
At lower
temperatures,
the dryer
might
not
shut off
at the
end
of an automatic
cycle.
This can
result
in
longer
drying
times.
The dryer
must not
be
installed
or stored
in an area where
it will
be exposed
to water
and/or
weather.
Check
code
requirements.
Some
codes
limit,
or do
not
permit,
installation
of the
dryer
in
garages,
closets,
mobile
homes
or sleeping
quarters.
Contact
your
local
building
inspector.
NOTE:
No
other
fuel-burning
appliance
can be installed
in the
same closet
as a dryer.
38"
(96.52
cm)
*Most
installations
require
a minimum
5" (12.7
cm)
clearance
behind
the
dryer
for the
exhaust
vent
with
elbow.
See "Venting
Requirements."
Installation
spacing
for
recessed
area
or
closet
installation
The following
spacing
dimensions
are recommended
for this
dryer.
This dryer
has been
tested
for spacing
of 0" (0 cm)
clearance
on
the
sides and
rear.
Recommended
spacing
should
be
considered
for the
following
reasons:
Additional
spacing
should
be considered
for ease of
installation
and
servicing.
Additional
clearances
might
be
required
for wall,
door
and
floor
moldings.
Additional
spacing
should
be considered
on
all sides of the
dryer
to
reduce
noise
transfer.
For closet
installation,
with
a doo_;
minimum
ventilation
openings
in the top
and
bottom
of the
door
are required.
I.ouvered
doors
with
equivalent
ventilation
openings
are
acceptable.
Companion
appliance
spacing
should
also
be considered.
Custom
undercounter
installation
- Dryer
only
Installation
clearances
The location
must be large enough to allow
the dryer door to open fully.
1"*
---_
I-_---27"--_11_-
1"*
(2.5cm)
(68.6
cm)
(2.5
cm)
*Required
spacing