NEC PX-50XM1A 50MP1 - Page 50

SHARPNESS Gain Data, CONTRAST Gain Data, BRIGHT Gain Data, Input MODE Request, RESET, COLOR TEMP

Page 50 highlights

11. SHARPNESS Gain Data Function The external control equipment changes the SHARPNESS gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag DATA01: SHARPNESS Gain Flag DATA02: SHARPNESS Gain 01H 06H F0H: -16 FFH: -01 00H: 0 01H: +01 10H:+16 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: SHARPNESS Gain Flag 06H 12. CONTRAST Gain Data Function The external control equipment changes the CONTRAST gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag DATA01: CONTRAST Gain Flag DATA02: CONTRAST Gain 01H 07H CCH: -52 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: BRIGHT Gain Flag 08H 14. Input MODE Request Function The display returns the current input information by the external control equipment' s request. Transmission Data 1FH 80H 60H 41H 00H CKS ACK 7FH 60H 80H 41H 01H DATA00 CKS DATA00: Input Select 01H: Video1 03H: Video3 05H: RGB1/PC1 0AH:DVD (DVD1) 0DH:DVD2 02H: Video2 04H: HD (HD1 or DTV or DTV1) 06H: RGB2/PC2 0CH:HD2 (DTV2) 0EH:RGB3/PC3 15. RESET Function The external control equipment resets the user adjustment of the plasma monitor. Transmission Data 1FH 80H 60H 54H 00H CKS ACK 3FH 60H 80H 54H 00H CKS FFH: -01 00H: 0 01H: +01 14H: +20 ACK 7FH 60H 80H 7FH 02H DATA00 DATA01 CKS DATA00: USER PICTURE Gain Flag 01H DATA01: CONTRAST Gain Flag 07H 13. BRIGHT Gain Data Function The external control equipment changes the BRIGHT gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00: USER PICTURE Gain Flag DATA01: BRIGHT Gain Flag DATA02: BRIGHT Gain 01H 08H E0H: -32 FFH: -01 00H: 0 01H: +01 16. COLOR TEMP SELECT Function The external control equipment changes the COLOR TEMP of the plasma monitor. Transmission Data DFH 80H 60H 00H 01H DATA00 CKS DATA00 ACK 00H: 1 01H: 2 02H: 3 03H: PRO 7FH 60H 80H 00H 01H DATA00 CKS DATA00: 00H: 1 01H: 2 02H: 3 03H: PRO NOTE: Set so that at the selection of 1, 2, or 3 of COLOR TEMP change of the following R/G/B GAIN data cannot be accepted. 20H: +32 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

43
11. SHARPNESS Gain Data
Function
The external control equipment changes the SHARPNESS gain data of the
plasma monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02
CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
SHARPNESS Gain Flag
06H
DATA02:
SHARPNESS Gain
F0H: -16
FFH: -01
00H: 0
01H: +01
10H:+16
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01
CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
SHARPNESS Gain Flag
06H
12. CONTRAST Gain Data
Function
The external control equipment changes the CONTRAST gain data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02
CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
CONTRAST Gain Flag
07H
DATA02:
CONTRAST Gain
CCH: -52
FFH: -01
00H: 0
01H: +01
14H: +20
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01
CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
CONTRAST Gain Flag
07H
13. BRIGHT Gain Data
Function
The external control equipment changes the BRIGHT gain data of the plasma
monitor.
Transmission Data
DFH
80H
60H
7FH
03H
DATA00 DATA01 DATA02
CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
BRIGHT Gain Flag
08H
DATA02:
BRIGHT Gain
E0H: -32
FFH: -01
00H: 0
01H: +01
20H: +32
ACK
7FH
60H
80H
7FH
02H
DATA00 DATA01
CKS
DATA00:
USER PICTURE Gain Flag
01H
DATA01:
BRIGHT Gain Flag
08H
14. Input MODE Request
Function
The display returns the current input information by the external control
equipment’ s request.
Transmission Data
1FH
80H
60H
41H
00H
CKS
ACK
7FH
60H
80H
41H
01H
DATA00
CKS
DATA00:
Input Select
01H: Video1
02H: Video2
03H: Video3
04H: HD (HD1 or DTV or DTV1)
05H: RGB1/PC1
06H: RGB2/PC2
0AH:DVD (DVD1)
0CH:HD2 (DTV2)
0DH:DVD2
0EH:RGB3/PC3
15. RESET
Function
The external control equipment resets the user adjustment of the plasma
monitor.
Transmission Data
1FH
80H
60H
54H
00H
CKS
ACK
3FH
60H
80H
54H
00H
CKS
16. COLOR TEMP SELECT
Function
The external control equipment changes the COLOR TEMP of the plasma
monitor.
Transmission Data
DFH
80H
60H
00H
01H
DATA00
CKS
DATA00
00H: 1
01H: 2
02H: 3
03H: PRO
ACK
7FH
60H
80H
00H
01H
DATA00
CKS
DATA00:
00H: 1
01H: 2
02H: 3
03H: PRO
NOTE: Set so that at the selection of 1, 2, or 3 of COLOR TEMP
change of the following R/G/B GAIN data cannot be accepted.