NEC PX-84VP5A 84VM5 IG - Page 13

VIDEO WALL SETTING, Running Sense

Page 13 highlights

NEC Solutions (America), Inc. Visual Systems 84VP5/84VM5 Installation Guide (using four 42VM5 or 42VP5 Plasma Displays) (also a reference for optional Quad Mount used with 42VM5 or 42VP5) v1.3 *: This command is premised on the system configuration of two or more plasma monitor being a multi-system. When renewal of the PSC data based on this command is not carried out during a certain fixed period (about 2 seconds) during PLE LINK enforcement, each plasma monitor sets PSC data as FFH. Since this command is one-way traffic, there is no ACK. *DATA01: Please set up FFH, when you publish this command from external control apparatus. A master*1 sets up its own PSS data. As compared with its own PSS data, the plasma monitor after the master which received this command sets up the data of the larger one, and equips the output of a command with it. *DATA02: Please set up FFH, when you publish this command from external control apparatus. The 1st round which PSS data has not decided is FFH. *1: "Master" means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution. 14.VIDEO WALL SETTING Function External control apparatus sets 4screens or 9screens as a video wall. Transmission Data DFH 80H 60H F3H 03H DATA00 DATA01 DATA02 CKS DATA00: 01H:1 screen (Matrix display function does not work.) 04H:4 screens (2*2 video wall) 09H:9 screens (3*3 video wall) DATA 01: DATA 02: 00H-FFH:Master's ID*1 01H : Video1 02H : Video2 03H : Video3 04H : HD (HD1 or DTV or DTV1) 05H : HD2 (DTV2) 06H : HD3 (DTV3) 07H : RGB1 / PC1 08H : RGB2 / PC2 09H : RGB3 / PC3 *: This command is used to following system. 1. The system configuration is video wall system (4screens or 9screens). 2. The ID number from a master1 display is set the continuous number. DATA00: Specify the composition of a multi-system. DATA01: Set master's ID*1. *1: "Master" means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution. 15.Running Sense Function External control apparatus grasps the power supply state of a plasma monitor. A plasma monitor is made to recognize connection of PC CONTROL. Transmission Data 1FH 80H 60H 88H 00H CKS ACK 7FH 60H 80H 88H 01H DATA CKS DATA: Bit0:Connect Condition 0: No connection 1: Connected Bit1: 0: Fixed 1:- www.necvisualsystems.com Page 13 of 14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

NEC Solutions (America), Inc.
Visual Systems
84VP5/84VM5 Installation Guide
(using four 42VM5 or 42VP5 Plasma Displays)
(also a reference for optional Quad Mount used with 42VM5 or 42VP5)
v1.3
www.necvisualsystems.com
Page 13 of 14
*: This command is premised on the system configuration of two or more plasma monitor being a multi-system. When
renewal of the PSC data based on this command is not carried out during a certain fixed period (about 2 seconds) during
PLE LINK enforcement, each plasma monitor sets PSC data as FFH. Since this command is one-way traffic, there is no
ACK.
*DATA01: Please set up FFH, when you publish this command from external control apparatus. A master
*1
sets up its own
PSS data. As compared with its own PSS data, the plasma monitor after the master which received this command sets up
the data of the larger one, and equips the output of a command with it.
*DATA02: Please set up FFH, when you publish this command from external control apparatus. The 1st round which PSS
data has not decided is FFH.
*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.
14.VIDEO WALL SETTING
Function
External control apparatus sets 4screens or 9screens as a video wall.
Transmission Data
DFH 80H 60H F3H 03H DATA00 DATA01 DATA02 CKS
DATA00:
01
H:
1 screen
(Matrix display function does not work.)
04
H:
4 screens (2*2 video wall)
09H
9 screens (3*3 video wall)
DATA 01:
00H-FF
H:
Master’s
ID
*1
DATA 02:
01H : Video1
02H : Video2
03H : Video3
04H : HD (HD1 or DTV or DTV1)
05H : HD2 (DTV2)
06H : HD3 (DTV3)
07H : RGB1 / PC1
08H : RGB2 / PC2
09H : RGB3 / PC3
*: This command is used to following system.
1. The system configuration is video wall system (4screens or 9screens).
2. The ID number from a master
1
display is set the continuous number.
DATA00: Specify the composition of a multi-system.
DATA01: Set master’s ID
*1
.
*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.
15.Running Sense
Function
External control apparatus grasps the power supply state of a plasma monitor.
A plasma monitor is made to recognize connection of PC CONTROL.
Transmission Data
1FH 80H 60H 88H 00H CKS
ACK
7FH 60H 80H 88H 01H DATA CKS
DATA: Bit0:Connect Condition
0: No connection
1: Connected
Bit1:
0: Fixed
1:-