NordicTrack Space Saver Se7i English Manual - Page 23

Maintenance And Troubleshooting

Page 23 highlights

MAINTENANCE AND TROUBLESHOOTING MAINTENANCE Inspect and tighten all parts of the elliptical regularly. Replace any worn parts immediately. To clean the elliptical, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight. CONSOLE TROUBLESHOOTING If the console does not turn on, make sure that the power cord is fully plugged in. Next, remove the four M4 x 37 16mm Screws (not shown) from the Large 27 Storage Foot (27), and then remove the Large Storage Foot. Then, remove the two M4 x 16mm Screws (not shown) from the Top Shield (37), and then use a flat screwdriver to pry the Top Shield upward off the elliptical. If lines appear in the console display, see HOW TO CHANGE CONSOLE SETTINGS on page 21 and adjust the contrast level of the display. Look into the access opening and locate the Reed Switch (58). Rotate the Pulley (66) until a Magnet (41) is aligned with the Reed Switch. If the console does not display your heart rate when you hold the handgrip heart rate monitor, or if the displayed heart rate appears to be too high or too low, see step 5 on page 16. HOW TO CALIBRATE THE INCLINE SYSTEM 61 41 58 If the incline frame is not functioning properly, it may 66 need to be calibrated. To calibrate the incline frame, press and hold the Calorie button for several seconds until the test mode appears in the display. Next, press the Calorie button again. Then, press the Incline increase or decrease button to calibrate the incline frame. The incline frame will move upward and downward as it calibrates. When the incline frame stops moving, it is calibrated. Then, press the Calorie button repeatedly to exit the calibration mode. HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, first press the power switch to the off position and unplug the power cord. Next, loosen, but do not remove, the two indicated M4 x 16mm Screws (61). Slide the Reed Switch (58) slightly toward or away from the Magnet (41). Then, retighten the M4 x 16mm Screws. Plug in the power cord, press the power switch to the reset position, and rotate the pulley for a moment. Repeat these actions until the console displays correct feedback. When the reed switch is correctly adjusted, press the power switch to the off position, unplug the power cord and reattach the top shield and the large storage foot. Then, plug in the power cord. 23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

23
MAINTENANCE
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap.
IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power cord is fully plugged in.
If lines appear in the console display, see HOW TO
CHANGE CONSOLE SETTINGS on page 21 and
adjust the contrast level of the display.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
step 5 on page 16.
HOW TO CALIBRATE THE INCLINE SYSTEM
If the incline frame is not functioning properly, it may
need to be calibrated. To calibrate the incline frame,
press and hold the Calorie button for several seconds
until the test mode appears in the display.
Next, press the Calorie button again. Then, press the
Incline increase or decrease button to calibrate the
incline frame. The incline frame will move upward and
downward as it calibrates.
When the incline frame stops moving, it is calibrated.
Then, press the Calorie button repeatedly to exit the
calibration mode.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. To adjust the reed
switch, first
press the power switch to the off posi-
tion and unplug the power cord.
Next, remove
the four M4 x
16mm Screws
(not shown)
from the Large
Storage Foot
(27), and then
remove the Large
Storage Foot.
Then, remove the
two M4 x 16mm
Screws (not shown) from the Top Shield (37), and then
use a flat screwdriver to pry the Top Shield upward off
the elliptical.
Look into the access opening and locate the Reed
Switch (58). Rotate the Pulley (66) until a Magnet (41)
is aligned with the Reed Switch.
Next, loosen, but do not remove, the two indicated
M4 x 16mm Screws (61). Slide the Reed Switch (58)
slightly toward or away from the Magnet (41). Then,
retighten the M4 x 16mm Screws.
Plug in the power cord, press the power switch to the
reset position, and rotate the pulley for a moment.
Repeat these actions until the console displays correct
feedback.
When the reed switch is correctly adjusted, press the
power switch to the off position, unplug the power cord
and reattach the top shield and the large storage foot.