Item RESET C GAMMA FILTER RESET M GAMMA FILTER RESET Y GAMMA FILTER RESET K GAMMA FILTER Color Menu The default settings are bold. Value EXECUTE EXECUTE EXECUTE Description Reset the stored TRC data (retained for tracking). For example, correct values could not be taken due to "out of order" situation. This is mainly for maintenance purposes and not ordinarily used. EXECUTE Block Device Menu The default settings are bold. Item INITIALIZE LOCK Value YES, NO Description Change to YES to block the operator panel from showing FLASH INITIALISE ITEM and PS FLASH RESIZE ITEM in the Disk maintenance and Memory menus. Item PEAK POWER CONTROL Peak Power Control Menu The default settings are bold. Value NORMAL, LOW Description Sets Peak Power Control. ES 2024/2024e Setting up • 75