Oki MICROLINE 186 Plus - Serial Users Guide - Page 38
Changing the Emulation Default in the Printer Menu
View all Oki MICROLINE 186 Plus - Serial manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
ML186 Plus Emulation Mode IBM Epson ML Compatible Printers/Drivers IBM 2480 IBM Graphics Printer Plus IBM Graphics Printer Epson ESC/P2 Epson LX Plus Epson LX Okidata MICROLINE Standard Changing the Emulation Default in the Printer Menu The default for the emulation in the printer menu is IBM. If you wish to change the menu default to another emulation: 1. Make sure continuous forms paper is loaded. 2. Turn the printer off. 3. Press and hold SELECT while turning the printer back on. The printer enters the menu mode. 4. Press FORM FEED. The first line of the menu prints, showing the emulation engaged. For example: Printer Control Emulation Mode IBM 5. Press TOF SET once or twice until the emulation you wish to engage appears in the right-hand column. Each time you press TOF SET, a new line prints and the setting which appears in the last column changes. For example: Printer Control Printer Control Emulation Mode Emulation Mode Epson ML 6. Press PITCH and MODE together to save your setting and exit the printer menu. 38 • Setting Up Your Printer