Oki ML421 Maintenance Manual - Page 18
B Receptacle Upstream Input to the USB Device
View all Oki ML421 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Oki Data CONFIDENTIAL (2) Universal Serial Bus (USB) Universal Serial Bus Specification Revision 1.0 compliance. 1) Connector • Printer Side • Cable Side : "B" Receptacle (Upstream Input to the USB Device) : Series "B" Plug 2) Cable • Cable Length : Approx 1.8m (A cable must be met USB Spec Rev 1.1 for normal operation) Note: Cable is not supplied. 3) Table of USB I / F signals Contact Number 1 2 3 4 Shell Signal Name Vbus D D + GND Shield Typical Wiring Assignment Red White Green Black Drain Wire 4) Connector pin arrangement 2 1 3 4 5) Mode & Class of Device • Full - speed Driver • Self - powered Device 6) Data Signaling Rate • Full - speed function - 12Mb/s ± 0.25%(2500ppm) 7) Receive Buffer • 2044K Bytes 8) Interface circuit TxD+ Full-speed Buffer Rs 3.3 V 1.5 kΩ Rs TxD- Rs = 22 Ω 42113901 Rev.2 18 /