4 Press the 9 or 0 button to select the set- ting. • To go to the main menu screen Mode: after the sub menu setting, select [Main Menu] from the HQ sub menu screen. 5 Press the PLAY/OK (`) button to confirm the setting. 6 Press the STOP (4) button to close the menu. Note: • The recorder will stop if you leave it idle for 3 minutes during a menu setup operation, when a selected item is not applied. h Recording Modes [Rec Mode] The recording mode can be chosen from [HQ] (high quality sound recording), [SP] (standard recording), and [LP] (long-term recording). In Menu mode selection: VN-5200PC Mode: HQ Mode: SP Mode: LP Approx. 35 hours Approx.69 hours Approx.221hours 20 minutes 35 minutes 30 minutes VN-3200PC Approx. 8 hours Approx. 17 hours Approx. 54 hours 40 minutes 10 minutes 40 minutes Current recording mode 05m35s 00m00s Notes: • The recording time shown above is for one continuous file. The available recording time may be shorter than specified if several files are recorded. (Use the remaining time and recorded time only as references.) • The above-noted recording times indicate times after deletion of the manual data stored in the recorder. h Microphone Sensitivity [Mic Sense] Microphone sensitivity is adjustable to meet your recording needs. In Menu mode selection: Microphone sensitivity indicator Sense: Conf. (g) Sense: Dict. (i) Note: • To ensure successful recording, make a test recording to select appropriate microphone sensitivity before recording. 05m35s 00m00s h Using the Variable Control Voice Actuator [VCVA] When the microphone senses that sound has reached a preset volume, the built-in Variable Control Voice Actuator (VCVA) starts recording automatically, and stops it when the volume drops. In Menu mode selection: VCVA indicator VCVA: Off VCVA: On Adjust the Start/Stop Actuation Level: 1 While the recorder is during recording mode, press the 9 or 0 buttons to adjust the pause sound level. • The VCVA level can be set to any of 15 different values. a VCVA Level b Start level (moves to the right/left according to the set level) 05m35s a 05m35s 00m00s 00m00s Note: b • The record/play indicator light is lit during recording. When the recorder is in Standby mode, the Record/Play indicator light flashes and [VCVA] flashes on the display. -8-

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

8
-
-
When the microphone senses that sound has reached a preset volume, the built-in Variable Control
Voice Actuator (VCVA) starts recording automatically, and stops it when the volume drops.
In Menu mode selection:
VCVA:
Off
VCVA:
On
Note:
• The recorder will stop if you leave it idle for 3 minutes during a menu setup operation, when a
selected item is not applied.
5
Press the
PLAY
/
OK
(
`
) button to confirm the
setting.
VCVA indicator
h
Recording Modes [
Rec Mode
]
Current recording mode
Microphone
sensitivity indicator
h
Microphone Sensitivity [
Mic Sense
]
h
Using the Variable Control Voice Actuator [
VCVA
]
Adjust the Start/Stop Actuation Level:
The recording mode can be chosen from [
HQ
] (high quality sound recording), [
SP
] (standard
recording), and [
LP
] (long-term recording).
In Menu mode selection:
Mode: HQ
Mode: SP
Mode: LP
VN-5200PC
Approx. 35 hours
20 minutes
Approx.69 hours
35 minutes
Approx. 221 hours
30 minutes
VN-3200PC
Approx. 8 hours
40 minutes
Approx. 17 hours
10 minutes
Approx. 54 hours
40 minutes
Notes:
The recording time shown above is for one continuous file. The available recording time may be
shorter than specified if several files are recorded. (Use the remaining time and recorded time
only as references.)
The above-noted recording times indicate times after deletion of the manual data stored in the
recorder.
Microphone sensitivity is adjustable to meet your recording needs.
In Menu mode selection:
Sense: Conf. (
g
)
Sense: Dict. (
i
)
Note:
• To ensure successful recording, make a test recording to select
appropriate microphone sensitivity before recording.
1
While the recorder is during recording mode,
press the
9
or
0
buttons to adjust the pause
sound level.
The VCVA level can be set to any of 15 different values.
a
VCVA Level
b
Start level (moves to the right/left according to the set level)
Note:
The record/play indicator light is lit during recording. When the recorder is in Standby mode, the
Record/Play indicator light flashes and [
VCVA
] flashes on the display.
Mode:
HQ
05m35s
00m00s
05m35s
00m00s
05m35s
00m00s
05m35s
00m00s
a
b
6
Press the
STOP (
4
)
button to close the menu.
4
Press the
9
or
0
button to select the set-
ting.
To go to the main menu screen
after the sub menu setting,
select [
Main Menu