    INSTRUCTION MANUAL 10 series Plus Blood Pressure Monitor with ComFitTM Cuff Model BP791IT ESPAÑOL ENGLISH
  • Omron 10 Series Plus | Instruction Manual - Page 2
    Instructions Know Your Unit 9 Unit Display 11 Display Symbols 12 Irregular Heartbeat Symbol 12 Movement Error Symbol 12 USER ID Symbol 12 Morning Hypertension Symbol 13 Heartbeat Symbol 14 Average Value Symbol 14 Morning Average Symbol 14 Evening Average Symbol 14 Cuff Wrap Guide
  • Omron 10 Series Plus | Instruction Manual - Page 3
    Memory 44 Downloading Instructions Installing the Software 45 Downloading and Installing Microsoft® HealthVaultTM 45 Downloading and Installing Omron Health Management Software 47 Using the Software 49 Care and Maintenance Care and Maintenance 53 Error Indicators and Troubleshooting Tips 55
  • Omron 10 Series Plus | Instruction Manual - Page 4
    comes with the following components: • Monitor • ComFitTM Cuff • 4 "AA" Alkaline Batteries • Storage Case • Instruction Manual printed in English and Spanish • Quick Start Guide • AC Adapter • USB Cable The BP791IT 10 series Plus Automatic Blood Pressure Monitor is intended for home use
  • Omron 10 Series Plus | Instruction Manual - Page 5
    to diagnose and treat High Blood Pressure. The monitor is not intended to be a diagnostic device. If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately. Read all of the information in the instruction manual and any other literature in
  • Omron 10 Series Plus | Instruction Manual - Page 6
    device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions. Read the Special Conditions section (page 37) of the instruction manual if your systolic pressure is known to be more than
  • Omron 10 Series Plus | Instruction Manual - Page 7
    the device into the appropriate voltage outlet. CARE AND MAINTENANCE Do not subject the monitor to strong shocks, such as dropping the unit on the floor. Do not modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.
  • Omron 10 Series Plus | Instruction Manual - Page 8
    Sit on a chair with your feet flat on the floor. Rest your arm on a table so that the cuff is at the same level as your heart. 6. Remain still and do not talk during the measurement. 7. Keep a record of your blood pressure and pulse readings for your physician. A single measurement may not provide
  • Omron 10 Series Plus | Instruction Manual - Page 9
    Operating Instructions KNOW YOUR UNIT Main Unit: Display Calibration Check System SET Button USER ID Selection Switch Up/Down ( / ) Buttons Morning/Evening Average ( ) Button Memory ( ) Button Start/Stop Button Battery Compartment USB Port Air Jack AC Adapter Jack 9
  • Omron 10 Series Plus | Instruction Manual - Page 10
    UNIT Components: Air Tube Housing Cord Air Plug (Connects to Air Jack) Arm Cuff AC Adapter 4 "AA" Alkaline Batteries Storage Case USB Cable INSTRUCTION MANUAL 10 series Plus Blood Pressure Monitor with ComFitTM Cuff Model BP791IT ESPAÑOL ENGLISH Quick Start Guide Instruction Manual 10
  • Omron 10 Series Plus | Instruction Manual - Page 11
    Blood Pressure Diastolic Blood Pressure Heartbeat Symbol Low Battery Indicator Morning Average Symbol Evening Average Symbol Irregular Heartbeat Symbol Average Value Symbol Memory Symbol Morning Hypertension Symbol Movement Symbol Blood Pressure Level Indicator Deflation Symbol Cuff Wrap Guide
  • Omron 10 Series Plus | Instruction Manual - Page 12
    ERROR SYMBOL ( ) The Movement Error Symbol is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2-3 minutes. Take another measurement, remain still during inflation. USER ID SYMBOL ( / ) The USER ID Symbol indicates USER A or USER B as selected by the user
  • Omron 10 Series Plus | Instruction Manual - Page 13
    morning average reading for a week is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value when viewing the Morning Averages and the Evening Averages in the memory. Omron Healthcare recommends you contact your physician if the MORNING HYPERTENSION SYMBOL
  • Omron 10 Series Plus | Instruction Manual - Page 14
    is displayed when viewing Evening Averages using the Memory Function. CUFF WRAP GUIDE SYMBOL ( / ) When the cuff is wrapped around the arm correctly, ( ) is displayed while taking a measurement or using the memory function. If the cuff is not wrapped around the arm correctly, ( ) is displayed. 14
  • Omron 10 Series Plus | Instruction Manual - Page 15
    power unit (AC Adapter) is intended to be correctly oriented in a vertical or floor mount position. NOTES: • Use only the authorized Omron AC Adapter that came with this monitor. • We recommend you install the batteries even if the AC Adapter is used. If no batteries are installed, you may need to
  • Omron 10 Series Plus | Instruction Manual - Page 16
    Cord TO DISCONNECT THE AC ADAPTER ① Hold the Housing to remove the AC Adapter from the electrical outlet. ② Remove the AC Adapter plug from the monitor. WARNING Do not plug or unplug the power cord into the electrical outlet with wet hands. WARNING Do not overload power outlets. Plug the device
  • Omron 10 Series Plus | Instruction Manual - Page 17
    direction of the arrow. 2. Install 4 "AA" size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated. Battery Cover 3. Replace the battery cover. 17
  • Omron 10 Series Plus | Instruction Manual - Page 18
    appears on the display screen turn the monitor off and remove all the batteries. Replace with four new batteries at the same time of clean water. Contact a physician immediately. NOTES: • Turn the unit off before replacing the batteries. If the batteries are removed while the unit is still on, the
  • Omron 10 Series Plus | Instruction Manual - Page 19
    . The Blood Pressure Monitor automatically stores up to 100 measurement values per user with the dates and times. The monitor also calculates last seven weeks. The monitor can also calculate an average reading based on the three most recent measurements taken within 10 minutes of the last reading
  • Omron 10 Series Plus | Instruction Manual - Page 20
    SETTING THE DATE AND TIME 1. TO START THE SETTING Press and hold the SET button to adjust the date and time. The year flashes on the display. 2. SETTING THE YEAR The year can be set between 2010 and 2040. When the display reaches 2040, it will return to 2010. Press the Up button ( ) to advance by
  • Omron 10 Series Plus | Instruction Manual - Page 21
    SETTING THE DATE AND TIME 3. SETTING THE MONTH Press the Up button ( ) to advance by one month. Press the SET button to set the current month. The day flashes on the display. 4. SETTING THE DAY Press the Up button ( ) to advance by one day. Press the SET button to set the current day. The hour
  • Omron 10 Series Plus | Instruction Manual - Page 22
    display. 6. SETTING THE MINUTE Press the Up button ( ) to advance by one minute. Press the SET button to set the minute setting. 7. TO TURN THE MONITOR OFF Press the START/STOP button. 22
  • Omron 10 Series Plus | Instruction Manual - Page 23
    SETTING TRUREADTM The TruReadTM Mode takes three consecutive measurements. The monitor will inflate, take a measurement, and deflate three times separated by a short interval of time between each measurement. 1. Select your USER ID (A or B). 2. Press the SET button. The TruReadTM symbol on the
  • Omron 10 Series Plus | Instruction Manual - Page 24
    SETTING TRUREADTM 4. Press the SET button to confirm the change. If on is selected, the number of seconds between each measurement is displayed. NOTE: The default value between each measurement is 60 seconds. 5. Press the Up or Down button ( / ) to change the interval of time between each
  • Omron 10 Series Plus | Instruction Manual - Page 25
    SETTING TRUREADTM 7. If the date and time are correct, press the START/STOP button to turn the monitor off. To change the date and time, refer to "Setting the Date and Time". 25
  • Omron 10 Series Plus | Instruction Manual - Page 26
    APPLYING THE ARM CUFF CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons
  • Omron 10 Series Plus | Instruction Manual - Page 27
    APPLYING THE ARM CUFF 3. Sit on a chair with your feet flat on the floor. Place your left arm on a table so the cuff is level with your heart. 4. Hold the thumb grip on the cuff securely with your right hand. Thumb Grip Cloth Fastener 5. Turn the palm of your left hand upward. 27
  • Omron 10 Series Plus | Instruction Manual - Page 28
    APPLYING THE ARM CUFF 6. Apply the cuff to your left upper arm so the blue stripe is on the inside of your arm and aligned with your middle finger. The air tube runs down the inside of your arm. The bottom of the cuff should be approximately 1/2" above your elbow. Blue Stripe 1/2 inch (1 - 2 cm)
  • Omron 10 Series Plus | Instruction Manual - Page 29
    APPLYING THE ARM CUFF APPLYING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm use this instruction for Step 6 on page 28. Apply the cuff to your right upper arm so the thumb grip is centered on the inside of your inner arm. The bottom of the cuff should be approximately
  • Omron 10 Series Plus | Instruction Manual - Page 30
    . If an error is detected, the Calibration Check System light flashes and "ER" will appear on the display. CUFF WRAP GUIDE This monitor checks whether the arm cuff is wrapped around the arm correctly during the inflation. When the cuff is wrapped correctly, is displayed while taking a measurement or
  • Omron 10 Series Plus | Instruction Manual - Page 31
    /STOP button. The cuff starts to inflate automatically. NOTE: To stop the inflation press the START/STOP button. The monitor will stop inflating, start deflation and turn off. 3. Inflation stops and the measurement is started. When the measurement is completed, your blood pressure and pulse rate
  • Omron 10 Series Plus | Instruction Manual - Page 32
    are used to calculate the Morning Averages and Evening Averages. Slide the USER ID Selection Switch right or left to select USER A or B. USING THE USER ID After you select a USER ID, the monitor can be set to take one measurement using the Single Mode or three consecutive measurements using the
  • Omron 10 Series Plus | Instruction Manual - Page 33
    Symbol you selected flashes on the display. The cuff starts to inflate automatically. As the cuff inflates, the monitor automatically determines your ideal inflation level. This monitor detects the pulse during inflation. Do not move your arm and remain still until the entire measurement process is
  • Omron 10 Series Plus | Instruction Manual - Page 34
    . The Heartbeat Symbol ( ) flashes at every heartbeat. 4. When the measurement is complete, the arm cuff completely deflates. Your blood pressure and pulse rate are displayed. 5. Press the START/STOP button to turn the monitor off. NOTE: The monitor will automatically turn off after two minutes. 34
  • Omron 10 Series Plus | Instruction Manual - Page 35
    the measurement is complete, the arm cuff completely deflates. NOTE: Do not move your arm and remain still until the entire measurement process is completed. 4. Check the progress of the consecutive measurements. NOTE: If a measurement fails, the monitor will repeat taking a measurement up to five
  • Omron 10 Series Plus | Instruction Manual - Page 36
    and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider. WARNING DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is
  • Omron 10 Series Plus | Instruction Manual - Page 37
    /STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure. NOTES: • Do not apply more pressure than necessary. • The monitor will not inflate above 299 mmHg. When the measurement is complete, the arm cuff completely deflates. Your blood pressure and pulse rate
  • Omron 10 Series Plus | Instruction Manual - Page 38
    and the pulse rate in the memory for two people (USER A and USER B) every time a measurement is completed. The monitor automatically stores up to 100 sets of measurement values (blood pressure and pulse rate) for each user (A and B). When 100 sets of measurement values are stored, the oldest
  • Omron 10 Series Plus | Instruction Manual - Page 39
    USING THE MEMORY FUNCTION TO DISPLAY THE MEASUREMENT VALUES 1. Select your USER ID (A or B). 2. Press the Memory button ( ). The Average Symbol ( ) appears on the display when the average reading is shown. 39
  • Omron 10 Series Plus | Instruction Manual - Page 40
    USING THE MEMORY FUNCTION 3. Press the Down button ( ) to display the most recent set of measurement values on the screen. The values are displayed from the most recent to the oldest. NOTE: The date and time are alternately displayed with the measurement values. Alternating display Press the Up
  • Omron 10 Series Plus | Instruction Manual - Page 41
    calculates and displays a weekly average for measurements taken in the morning ( ) and evening ( ). The monitor stores 8 weeks of Morning Averages and 8 weeks of Evening Averages for each user (A and B). NOTE: The week begins Sunday at 4:00 AM. MORNING AVERAGES Morning averages are based on the
  • Omron 10 Series Plus | Instruction Manual - Page 42
    USING THE MEMORY FUNCTION TO DISPLAY MORNING AND EVENING AVERAGES 1. Select your USER ID (A or B). 2. Press the Morning/ Evening Average button ( ) to select the Morning or Evening average. given week, the display will appear as illustrated. 4. Press the START/STOP button to turn the monitor off. 42
  • Omron 10 Series Plus | Instruction Manual - Page 43
    USING THE MEMORY FUNCTION DISPLAY COMBINATIONS In addition to the Morning Average and Evening Average Symbols, the monitor may also display the Morning Hypertension Symbol if the morning average for that week is above the internationally recognized guidelines. (See page 13 for details.)
  • Omron 10 Series Plus | Instruction Manual - Page 44
    STORED IN THE MEMORY The values stored in the memory are deleted by USER ID. You cannot partially delete values stored in the memory. All values for the user you select will be deleted. 1. Select your USER ID (A or B). 2. While holding the Memory button ( ) and the START/STOP button simultaneously
  • Omron 10 Series Plus | Instruction Manual - Page 45
    , choose either Microsoft® HealthVaultTM or Omron Health Management software. NOTE: Any measurement values taken before setting the date and time are not transferred to Microsoft HealthVaultTM and Omron Health Management software. DOWNLOADING AND INSTALLING MICROSOFT® HEALTHVAULTTM HealthVault is
  • Omron 10 Series Plus | Instruction Manual - Page 46
    INSTALLING THE SOFTWARE OPERATING ENVIRONMENT REQUIREMENTS The following operating environments are required to run Microsoft® HealthVault. Supported OS*: HealthVault works best with the following operating systems: Either 32-bit or 64-bit versions of: Microsoft® Windows® 7® Home Premium
  • Omron 10 Series Plus | Instruction Manual - Page 47
    THE SOFTWARE DOWNLOADING AND INSTALLING OMRON HEALTH MANAGEMENT SOFTWARE Omron Health Management Software allows you to view, process and print data about blood pressure and walking measured by Omron's compatible blood pressure monitor and pedometer. • To install Omron Health Management Software
  • Omron 10 Series Plus | Instruction Manual - Page 48
    are required to run the Omron Health Management software. Supported OS: PC: Memory capacity: Hard disc space: Display: Others: Microsoft® Windows® 2000 Professional (SP4) Microsoft® Windows® XP Home Edition (SP2) Microsoft® Windows® XP Professional (SP2) Microsoft® Windows® Vista® Home Basic
  • Omron 10 Series Plus | Instruction Manual - Page 49
    on the desktop: From the [Start] menu, select [All programs] or [Programs] [Omron Health Management Software], and click the [Omron Health Management Software] shortcut. 2. If you are using Omron Health Management Software for the first time, click [Add User] on the User Management screen. 49
  • Omron 10 Series Plus | Instruction Manual - Page 50
    Registration box, enter your name (e.g., Chuck) and click [OK]. NOTES: • Omron Health Management Software can manage multiple users' data. Data is controlled by user name. • The number of users who can register for this software varies depending on the amount of free disc space in your PC. • The
  • Omron 10 Series Plus | Instruction Manual - Page 51
    the authorized Omron USB cable, Model HHX-CABLEUSB2, included with this unit. CAUTION Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit. 1. Open the USB Port cover. 2. Plug the normal USB Connector (Large Connector) into
  • Omron 10 Series Plus | Instruction Manual - Page 52
    USING THE SOFTWARE 4. Click [Download Data] icon to import the data. 5. The Confirm dialog appears. Make sure your cable is connected then click [Yes]. 6. Select the blood pressure monitor being used and click [OK]. 7. Start importing data. Click [Cancel] if you want to cancel. 8. The dialog appears
  • Omron 10 Series Plus | Instruction Manual - Page 53
    To keep your blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below: Keep the monitor in the storage AC Adapter cord. Do not forcefully bend the arm cuff or air tube. Do not fold tightly. Clean the monitor with a soft dry cloth. Do not use
  • Omron 10 Series Plus | Instruction Manual - Page 54
    Use the unit consistent with the instruction provided in this manual. CAUTION Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components. CAUTION Use only Omron authorized parts and accessories. Parts and
  • Omron 10 Series Plus | Instruction Manual - Page 55
    TROUBLESHOOTING TIPS ERROR INDICATORS SYMBOL CAUSE Air plug disconnected. CORRECTION Insert the plug securely. Refer to "Applying the Arm Cuff". Arm cuff not applied correctly. Apply the arm cuff correctly. Refer to "Applying the Arm Cuff". Air is leaking from the arm cuff. Replace the cuff
  • Omron 10 Series Plus | Instruction Manual - Page 56
    ". TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS No power. Replace all four batteries with new ones. No display appears on the unit. Check the battery installation for proper placement of the battery polarities. Measurement values appear too high or too low. Blood pressure varies
  • Omron 10 Series Plus | Instruction Manual - Page 57
    installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that radio/TV technician for help. POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only) This digital apparatus does not exceed the Class B limits
  • Omron 10 Series Plus | Instruction Manual - Page 58
    Omron® BP791IT 10 series Plus Automatic Blood Pressure Monitor, excluding the arm cuff and batteries, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor. The arm
  • Omron 10 Series Plus | Instruction Manual - Page 59
    SPECIFICATIONS Model: BP791IT (HEM-7222-ITZ) Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic pressure
  • Omron 10 Series Plus | Instruction Manual - Page 60
    Manufactured by OMRON HEALTHCARE Co., Ltd. Made in China Distributed by: Omron Healthcare, Inc. 1200 Lakeside Drive Bannockburn, IL 60015 www.omronhealthcare.com Copyright © 2011 Omron Healthcare, Inc.
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

10 series
Plus
Blood Pressure Monitor
with ComFit
TM
Cuff
Model
BP791IT
INSTRUCTION MANUAL
ESPAÑOL
ENGLISH