Checking for ionizing needle operation., Using HV voltage probe, check needle for, high voltage -5.5
View all Oreck Air 6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Troubleshooting Guide f. If the H.V. contacts are not properly aligned or the contact wall is not properly aligned. The H.V. contacts must make good contact. Replace the contact wall or straighten the contacts, if possible. 7. Checking for ionizing needle operation. Using HV voltage probe check needle for high voltage -5.5 KVDC to -7.0 KVDC. a. If voltage is present, the ionizer is OK. Clean needle with alcohol and a cotton swab. b. If voltage is not present, check HV power supply. See above diagram. c. If voltage is present at HV power supply but not the needle. Replace the negative ionizer assembly including wire, with needle attached, and terminal. IMPORTANT: Replace using wire routing on contact board. 13
13
Troubleshooting Guide
f.
If the H.V. contacts are not properly aligned or the contact wall is not properly
aligned.
7.
Checking for ionizing needle operation.
Using HV voltage probe
check needle for
high voltage -5.5 KVDC to -7.0 KVDC.
a.
If voltage is present, the ionizer is OK.
b.
If voltage is not present, check HV power supply.
c.
If voltage is present at HV power supply but not the needle.
Clean needle with alcohol
and a cotton swab.
See above diagram.
Replace the negative ionizer
assembly including wire,
with needle attached, and
terminal.
IMPORTANT: Replace using
wire routing on contact
board.
The H.V. contacts must make
good contact.
Replace the
contact wall or straighten the
contacts, if possible.