Troubleshooting Service problems that appear to be major can often be solved easily. You can be your own troubleshooter by reviewing this guide. All other servicing should be done by an Oreck authorized service center. Problem Check Solution • Unit fails to steam • Heating indicator light does not illuminate, power light is illuminated but unit fails to steam • Not plugged in properly. • Be sure cleaner is firmly • Household circuit plugged into wall outlet. breaker/ground fault • Reset circuit breaker/ground interrupter has tripped or fault interrupter, or replace blown a fuse. fuse. If you need assistance contact a licensed electrician. Thermostat indicator light does illuminate, but unit fails to steam. • Mineral build-up in unit. • See De-scaling the Boiler • Unit may be suffering Tank on page 19. from internal mechanical • Unplug unit and contact problems. Customer support for repair or replacement assistance. Steam output is weak or intermittent. Mineral build-up in unit. It is normal for the unit to periodically stop steaming for a few seconds. If steam stays off for longer periods, follow the De-scaling the Boiler Tank instructions on page 19. • Excessive gurgling in hose handle. • Water drips from nozzle. • Water condensation in • Some gurgling is a natural hose/handle. effect of the steaming • Boiler has been overfilled process. For excessive gurgling or dripping water, point the nozzle towards the ground and shake to remove the excess water. • Empty some water out of the boiler so that is contains no more than 25 oz. of water. ... 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

±0
Troubleshooting
Service problems that appear to be major can often be solved
easily. You can be your own troubleshooter by reviewing this
guide. All other servicing should be done by an Oreck
authorized service center.
Problem
Check
Solution
Unit fails to steam
Heating indicator
light does not
illuminate,
power light is
illuminated but
unit fails to
steam
Not plugged in properly.
Household circuit
breaker/ground fault
interrupter has tripped or
blown a fuse.
Be sure cleaner is firmly
plugged into wall outlet.
Reset circuit breaker/ground
fault interrupter, or replace
fuse. If you need assistance
contact a licensed
electrician.
Thermostat
indicator light does
illuminate, but unit
fails to steam.
Mineral build-up in unit.
Unit may be suffering
from internal mechanical
problems.
See
De-scaling the Boiler
Tank
on page 19.
Unplug unit and contact
Customer support for repair
or replacement assistance.
Steam output is
weak or
intermittent.
Mineral build-up in unit.
It is normal for the unit to
periodically stop steaming for a
few seconds. If steam stays off
for longer periods, follow the
De-scaling the Boiler Tank
instructions on page 19.
Excessive
gurgling in hose
handle.
Water drips from
nozzle.
Water condensation in
hose/handle.
Boiler has been overfilled
Some gurgling is a natural
effect of the steaming
process. For excessive
gurgling or dripping water,
point the nozzle towards the
ground and shake to remove
the excess water.
Empty some water out of the
boiler so that is contains no
more than 25 oz. of water.