Oregon Scientific WMR90A User Manual - Page 8

Remote Wind Sensor Unit - wireless weather station

Page 8 highlights

EN Memory Alarm Current, min and max Hi / Lo RADIO-CONTROLLED / ATOMIC CLOCK Synchronization Auto or disabled Clock display HH:MM:SS Hour format 12hr AM/PM or 24hr Calendar DD/MM or MM/DD Weekday in 5 (E, G, F, I, S) languages Battery 4 x UM-3 (AA) 1.5V batteries AC adapter 6V REMOTE WIND SENSOR UNIT Weight 556 g (1.23 lbs) without battery Wind speed unit m/s, kph, mph, knots Speed accuracy 2 m/s ~ 10 m/s (+/- 3 m/s) 10 m/s ~ 56 m/s (+/- 10%) Direction accuracy 16 positions Transmission of Approx. every 14 seconds wind speed signal Memory Max speed gust OUTDOOR TEMPERATURE Temp. unit Displayed range Operating range Accuracy Comfort Memory °C / °F -50°C to 70°C (-58°F to 158°F) -30°C to 60°C (-4°F to 140°F) -20°C - 0°C: +/- 2°C (+/- 4.0°F) 0°C - 40°C: +/- 1°C (+/- 2.0°F) 40°C - 50°C: +/- 2°C (+/- 4.0°F) 50°C - 60°C: +/- 3°C (+/- 6.0°F) 20°C to 25°C (68°F to 77°F) Current, min and max temp. Dew Point w/ max and min Wind chill temp. and min RELATIVE HUMIDITY Displayed range Operating range Resolution Accuracy Comfort Memory 2% to 98% 25% to 90% 1% 25% - 40%: +/- 7% 40% - 80%: +/- 5% 80% - 90%: +/- 7% 40% to 70% Current, min and max RF TRANSMISSION RF frequency Range Transmission No. of Channel Battery 433MHz Up to 100 meters (328 feet) with no obstructions Approx. every 60 seconds 1 for Wind/ Rain/ UV and 10 for Temp. / Humidity 4 x UM-3 (AA) 1.5V REMOTE RAIN GAUGE Dimensions (L x W x H) Weight Rainfall unit Range Resolution Accuracy Memory Battery 107 x 87 x 56 mm (4.2 x 3.4 x 2.2 inches) 134 g (0.3 lbs) without battery Mm/hr and in/hr 0 mm/hr - 999 mm/hr 1 mm/hr < 15 mm/hr: +/- 1 mm 15 mm to 9999 mm: +/- 7% Past 24hrs, hourly and accumulated from last memory reset 2 x UM-3 (AA) 1.5V ABOUT OREGON SCIENTIFIC Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you're in the US and would like to contact our Customer Care department directly, please visit: www2.oregonscientific.com/service/support OR Call 1-800-853-8883. For international inquiries, please visit: www2.oregonscientific.com/about/international FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio / TV technician for help. DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com or on the warranty card for this product) for all inquiries instead. We Name: Oregon Scientific, Inc. Address: 19861 SW 95th Ave., Tualatin, Oregon 97062 USA Telephone No.: 1-800-853-8883 declare that the product Product No.: WMR90A Product Name: Advanced Weather Station with Wireless Sensor Set Manufacturer: IDT Technology Limited Address: Block C, 9/F, Kaiser Estate, Phase 1,41 Man Yue St., Hung Hom, Kowloon, Hong Kong is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

8
EN
Memory
Current, min and max
Alarm
Hi / Lo
RADIO-CONTROLLED / ATOMIC CLOCK
Synchronization
Auto or disabled
Clock display
HH:MM:SS
Hour format
12hr AM/PM or 24hr
Calendar
DD/MM or MM/DD
Weekday in 5
(E, G, F, I, S) languages
Battery
4 x UM-3 (AA) 1.5V batteries
AC adapter
6V
REMOTE WIND SENSOR UNIT
Weight
556 g (1.23 lbs) without battery
Wind speed unit
m/s, kph, mph, knots
Speed accuracy
2 m/s ~ 10 m/s (+/- 3 m/s)
10 m/s ~ 56 m/s (+/- 10%)
Direction accuracy
16 positions
Transmission of
Approx. every 14 seconds wind speed signal
Memory
Max speed gust
OUTDOOR TEMPERATURE
Temp. unit
°C / °F
Displayed range
-50°C to 70°C (-58°F to 158°F)
Operating range
-30°C to 60°C (-4°F to 140°F)
Accuracy
-20°C – 0°C: +/- 2°C (+/- 4.0°F)
0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
50°C - 60°C: +/- 3°C (+/- 6.0°F)
Comfort
20°C to 25°C (68°F to 77°F)
Memory
Current, min and max temp. Dew Point w/ max
and min Wind chill temp. and min
RELATIVE HUMIDITY
Displayed range
2% to 98%
Operating range
25% to 90%
Resolution
1%
Accuracy
25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%
Comfort
40% to 70%
Memory
Current, min and max
RF TRANSMISSION
RF frequency
433MHz
Range
Up to 100 meters (328 feet) with no obstructions
Transmission
Approx. every 60 seconds
No. of Channel
1 for Wind/ Rain/ UV and 10 for Temp. / Humidity
Battery
4 x UM-3 (AA) 1.5V
REMOTE RAIN GAUGE
Dimensions
107 x 87 x 56 mm
(L x W x H)
(4.2 x 3.4 x 2.2 inches)
Weight
134 g (0.3 lbs) without battery
Rainfall unit
Mm/hr and in/hr
Range
0 mm/hr – 999 mm/hr
Resolution
1 mm/hr
Accuracy
< 15 mm/hr: +/- 1 mm
15 mm to 9999 mm: +/- 7%
Memory
Past 24hrs, hourly and accumulated
from last
memory reset
Battery
2 x UM-3 (AA) 1.5V
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more about Oregon Scientific
products. If you’re in the US and would like to contact our Customer Care department
directly, please visit: www2.oregonscientific.com/service/support
OR
Call 1-800-853-8883.
For international inquiries, please visit: www2.oregonscientific.com/about/international
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
This device must accept any interference received, including interference that may
cause undesired operation.
WARNING
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
NOTE
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio / TV technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for support or sales. Please call
our customer service number (listed on our website at www.oregonscientific.com or
on the warranty card for this product) for all inquiries instead.
We
Name:
Oregon Scientific, Inc.
Address:
19861 SW 95th Ave., Tualatin, Oregon 97062 USA
Telephone No.:
1-800-853-8883
declare that the product
Product No.:
WMR90A
Product Name:
Advanced Weather Station with Wireless Sensor Set
Manufacturer:
IDT Technology Limited
Address:
Block C, 9/F, Kaiser Estate, Phase 1,41 Man Yue St.,
Hung Hom, Kowloon, Hong Kong
is in conformity with Part 15 of the FCC Rules.
Operation is subject to the following
two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference
received, including interference that
may cause undesired operation.