Panasonic AW-HE120K Operating Instructions - Page 48
Specifications
View all Panasonic AW-HE120K manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
Specifications Power requirements: DC 12 V (AC adaptor supplied) Current consumption: 1.75 A indicates safety information. INPUT Input connector: DC 12 V IN, G/L IN (BNC) BBS (Black Burst Sync), tri-level sync supported GENERAL Ambient operating temperature: 0 °C to +40 °C (32 °F to +104 °F) Storage temperature: -20 °C to +50 °C (-4 °F to +122 °F) Allowable humidity ranges: 35 % to 90 % (no condensation) Mass: Approx. 3.0 kg (6.61 lbs) [Including mount bracket] Dimensions (W H D): 180 mm 228 mm 220 mm (7-3/32 inches 8-31/32 inches 8-21/32 inches) [excluding protrusions, cable cover, direct ceiling mount bracket] Finish: AW-HE120W: Pearl white AW-HE120K: Metallic black Controller supported: AW-RP655, AW-RP555, AW-RP50 It may be necessary to upgrade the version of the controller so that the controller will support the unit. OUTPUT Video output HDMI: HDMI connector HDCP is not supported. Viera Link is not supported. HD/SD SDI OUT: Compliant with the SMPTE292M/ SMPTE259M standards/ 75 (BNC 1) VIDEO OUT: NTSC/PAL 1.0 V [p-p]/75 (BNC 1) HD/SD ANALOG OUT: Y/Pb/Pr or R/G/B D-sub 15-pin 1 INPUT/OUTPUT Input/Output connector LAN: LAN connector for IP control (RJ-45) RS-422: CONTROL IN RS422A (RJ-45) 48