continued, Submenu, Setting, Description, I-P MODE, ANAMO, SD ASPECT, ZEBRA INT. MIN., INT. MAX.

Page 28 highlights

Main Menu (continued) Submenu I-P MODE *7 MONO *2 ANAMO *8 SD ASPECT *2 SCAN *2*8 ZEBRA INT. MIN. *9 INT. MAX. *9 EXT. MIN. *9 EXT. MAX. *9 Setting MODE1 MODE2 OFF ON OFF ON 4:3 16:9 NORMAL UNDER -7% to 108% (Factory default setting: 70%) -6% to 109% (Factory default setting: 85%) -7% to 108% (Factory default setting: 5%) -6% to 109% (Factory default setting: 100%) Description Selects IP conversion mode. (see "IP mode" (→This page).) [MODE1] Intra-frame interpolation [MODE2] Intra-field interpolation Switches between color and monochrome (MONO). [OFF] Color [ON] Monochrome • When [ON], the [CHROMA] setting of the [PICTURE] (picture adjusting) menu is fixed at 0. With an Anamo lens and HD-SDI input, the picture is resized to Anamo magnification. (the vertically enlarged signal can be vertically compressed and corrected for display). Sets the aspect ratio for SD signal input. [4:3] 4:3 display [16:9] 16:9 display Sets under-scan and normal display. [NORMAL] Normal display [UNDER] Under-scan Sets the range of the ZEBRA function. Displays the minimum value of the INT. range as a percentage of the video signal. Sets the range of the ZEBRA function. Displays the maximum value of the INT. range as a percentage of the video signal. Sets the range of the ZEBRA function. Displays the minimum value of the EXT. range as a percentage of the video signal. Sets the range of the ZEBRA function. Displays the maximum value of the EXT. range as a percentage of the video signal. *2 This menu is grayed out when the same item is assigned to GPI and [GPI CONTROL] is set to [ENABLE]. *7 To use the SUB WINDOW (→page 38) function, A Change settings after exiting the SUB WINDOW function. B It is recommended to use [MODE2] for handling fast video. *8 [SCAN] changes are not reflected in Anamo size display. *9 The ZEBRA function must be set according to the following conditions. [INT. MIN.] < [INT. MAX.] [EXT. MIN.] < [EXT. MAX.] [EXT. MIN.] ≦ [INT. MIN.] [INT. MAX.] ≦ [EXT. MAX.] IP mode [MODE1] performs IP conversion using intra-frame interpolation. This monitor suppresses the delay to within 1 field. The factory default is [MODE1]. [MODE2] performs IP conversion using intra-field interpolation. Since interpolation is performed inside each field, this mode is suitable for checking interlace status. 28

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80

28
Main Menu
(continued)
Submenu
Setting
Description
I-P MODE
*
7
MODE1
MODE2
Selects IP conversion mode. (see “IP mode” (→This page).)
[MODE1] Intra-frame interpolation
[MODE2] Intra-field interpolation
MONO
*
2
OFF
ON
Switches between color and monochrome (MONO).
[OFF]
Color
[ON]
Monochrome
• When [ON], the [CHROMA] setting of the [PICTURE] (picture adjusting) menu is
fixed at 0.
ANAMO
*
8
OFF
ON
With an Anamo lens and HD-SDI input, the picture is resized to Anamo
magnification.
(the vertically enlarged signal can be vertically compressed and
corrected for display).
SD ASPECT
*
2
4:3
16:9
Sets the aspect ratio for SD signal input.
[4:3] 4:3 display
[16:9] 16:9 display
SCAN
*
2
*
8
NORMAL
UNDER
Sets under-scan and normal display.
[NORMAL] Normal display
[UNDER]
Under-scan
ZEBRA INT. MIN.
*
9
-7% to 108%
(Factory default
setting: 70%)
Sets the range of the ZEBRA function.
Displays the minimum value of the INT. range as a percentage of the video signal.
INT. MAX.
*
9
-6% to 109%
(Factory default
setting: 85%)
Sets the range of the ZEBRA function.
Displays the maximum value of the INT. range as a percentage of the video signal.
EXT. MIN.
*
9
-7% to 108%
(Factory default
setting: 5%)
Sets the range of the ZEBRA function.
Displays the minimum value of the EXT. range as a percentage of the video signal.
EXT. MAX.
*
9
-6% to 109%
(Factory default
setting: 100%)
Sets the range of the ZEBRA function.
Displays the maximum value of the EXT. range as a percentage of the video signal.
*
2
This menu is grayed out when the same item is assigned to GPI and [GPI CONTROL] is set to [ENABLE].
*
7
To use the SUB WINDOW (→page 38) function,
A
Change settings after exiting the SUB WINDOW function.
B
It is recommended to use [MODE2] for handling fast video.
*
8
[SCAN] changes are not reflected in Anamo size display.
*
9
The ZEBRA function must be set according to the following conditions.
[INT. MIN.] < [INT. MAX.]
[EXT. MIN.] < [EXT. MAX.]
[EXT. MIN.]
[INT. MIN.]
[INT. MAX.]
[EXT. MAX.]
IP mode
[MODE1] performs IP conversion using intra-frame interpolation.
This monitor suppresses the delay to within 1 field.
The factory default is [MODE1].
[MODE2] performs IP conversion using intra-field interpolation.
Since interpolation is performed inside each field, this mode is suitable for checking interlace status.