4.1 Troubleshooting 4.1.5 Troubleshooting by Error Log When a major system error occurs in the PBX, the ALARM indicator on the front of the cabinet turns on red, and the system logs the error information. Error Log Display Format Below is the display format of the error log. To see the error log using the KX-TAW848 Maintenance Console, refer to the on-line help of the KX-TAW848 Maintenance Console. Example: KX-TAW848 Maintenance Console 3 1 2 4 5 6 Example: Station Message Detail Recording (SMDR) 04/01/01 10:37AM MJ ALM #000 10000 MPR WDT overflow 04/01/01 11:07AM MN ALM #010 10000 AC power down 04/01/01 03:55PM MN ALM #392 10401 Clock master card selected 1 2 3 45 6 Description 1 Date 2 Time 3 Level Item 4 Error Code Description Date of the error detection Time of the error detection Major Alarm (MJ ALM): Errors that affect the whole system operation, or result in system failure Minor Alarm (MN ALM): Errors that affect certain part of system operation Three-digit error code Installation Manual 117