Motor Shaft Arbre d'entraînement du moteur Eje del motor Groove Ouverture Ranura Replacing Belt Lift Agitator Up Soulever l'agitateur Unidad del agitador ➢ Replace belt whenever a burning rubber smell caused by excessive slippage occurs. ➢ Place carpet-bare floor selector in CARPET position. ➢ Remove lower plate. ➢ Remove agitator by carefully lifting out. ➢ Remove worn or broken belt. Carpet-Bare Floor Selector Shaft Arbre du sélecteur tapis/plancher Eje del selector carpet-bare floor ➢ Clean agitator and reinstall the two (2) end caps. ➢ Loop new belt (Panasonic Type UB8 only) around motor shaft and brush pulley; see illustration for correct belt routing. ➢ Reinstall agitator back into nozzle housing grooves. ➢ After reinstalling the agitator, turn it by hand to make sure that belt is not twisted or pinched and that all rotating parts turn freely. ➢ Reinstall lower plate. End Cap Bouchon Tapa del extremo - 34 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

- 34 -
Replacing Belt
Lift Agitator Up
Soulever l’agitateur
Unidad del agitador
Carpet-Bare Floor
Selector Shaft
Arbre du sélecteur
tapis/plancher
Eje del selector
carpet-bare floor
Motor Shaft
Arbre d’entraînement
du moteur
Eje del motor
End Cap
Bouchon
Tapa del
extremo
Groove
Ouverture
Ranura
Replace belt whenever a burning
rubber smell caused by excessive
slippage occurs.
Place carpet-bare floor selector in
CARPET position.
Remove lower plate
.
Remove agitator by carefully lifting out.
Remove worn or broken belt.
Clean agitator and reinstall the two
(2) end caps.
Loop new belt (Panasonic Type UB8
only) around motor shaft and brush
pulley; see illustration for correct belt
routing.
Reinstall agitator back into nozzle
housing grooves.
After reinstalling the agitator, turn it
by hand to make sure that belt is not
twisted or pinched and that all
rotating parts turn freely.
Reinstall lower plate.