Panasonic PT-DW6300US Functional Instructions - Page 29

Lamp Select, Lamp Relay, Lamp Power, Standby Mode, Rs-232c, Remote2 Mode, English - 29 - replacement lamp for

Page 29 highlights

Settings PROJECTOR SETUP menu LAMP SELECT You can select a lamp lighting pattern for using environment. Press I H to cycle through options, and the ENTER button. DUAL SINGLE LAMP1 LAMP2 All lamps will light. Selects a lamp with shorter duration of use. Selects the Lamp unit 1. Selects the Lamp unit 2. NOTE: • If, in the SINGLE, LAMP1 or LAMP2 mode, one lamp remains off or the currently active lamp exceeds 2 000 hours of cumulative operating time (when HIGH is selected as the LAMP POWER setting), the other lamp will light. If, in the DUAL mode, one lamp remains off or the currently active lamp exceeds 2 000 hours of cumulative operating time (when HIGH is selected as the LAMP POWER setting), the other lamp alone will light. However, if both lamps remain off or the 2 000 hours of cumulative operating time (when HIGH is selected as the LAMP POWER setting) are exceeded, the projector will enter the standby mode. • The colours of the items indicate the status. Green: Current setting Yellow: Current setting (when a lamp fails or fails to light) Red: Lamp that has failed to light White: Any other status. • If the projector is repeatedly used for short periods of time, the lamps will need to be replaced more frequently. LAMP RELAY If using the projector for a continuous period of 24 hours or more, this setting can be used to automatically switch the lamps that are turned on in order to reduce the lamp deterioration that can occur as a result of continuous use. OFF 00:00 - 23:00 Deactive 1 hour interval from 00:00 to 23:00 NOTE: • Only when DUAL or SINGLE is selected in LAMP SELECT, LAMP RELAY is available. If LAMP1 or LAMP2 is selected, LAMP RELAY function is not available. LAMP SELECT setting SINGLE DUAL Repeated operation LAMP1 and LAMP2 light alternately by the set time, and the shorter duration of use lamp will light first. After both lamps light for the set time, only one lamp is turned off for 2 hours, then for only the other lamp for next 2 hours. The longer duration of use lamp will be turned off first. LAMP POWER The luminance of the projection lamp can be changed depending on user's needs or the viewing conditions. HIGH LOW Set when high brightness is necessary. Set when high brightness is not necessary. NOTE: • When set to LOW, it is possible to reduce power consumption, reduce operating noise and extend lamp service life. STANDBY MODE You can select the electrical consumption while in standby mode. NORMAL ECO The electrical consumption in standby mode is 10 W. The electrical consumption in standby mode is 0.5 W. NOTE: • With ECO setting, NETWORK function, RS-232C output and some of RS-232C commands are not available. When switch on the projector, projection will start about 10 seconds late. RS-232C This sets the communication parameters at the serial terminals. (IN) BAUDRATE Select 9600, 19200 or 38400. (IN) PARITY Select NONE, EVEN or ODD. (OUT) BAUDRATE Select 9600, 19200 or 38400. (OUT) PARITY Select NONE, EVEN or ODD. RESPONSE(ID ALL) Select ON or OFF. GROUP Select A to Z. RESPONSE(ID GROUP) Select ON or OFF. REMOTE2 MODE You can customise the REMOTE 2 IN terminal function. DEFAULT The pin assignment of the REMOTE 2 IN terminal is used as the projector default setting. USER For changing an optional input module or customising the pin assignments. PIN1 PIN2 PIN3 - PIN7 PIN8 PIN9 GND POWER H NONE RGB1 H RGB2 H VIDEO H S-VIDEO H DVID H BALLAST VERSION H REWIND ALL FILTER H NONE SHUTTER H NONE ENABLE H DISABLE ENGLISH - 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

PROJECTOR SETUP menu
E
NGLISH - 29
Settings
You can select a lamp lighting pattern for using environment.
Press
I
H
to cycle through options, and the
ENTER
button.
If using the projector for a continuous period of 24 hours or
more, this setting can be used to automatically switch the
lamps that are turned on in order to reduce the lamp
deterioration that can occur as a result of continuous use.
The luminance of the projection lamp can be changed
depending on user’s needs or the viewing conditions.
You can select the electrical consumption while in standby
mode.
This sets the communication parameters at the serial
terminals.
You can customise the
REMOTE 2 IN
terminal function.
DEFAULT
The pin assignment of the
REMOTE 2 IN
terminal is used as the projector default
setting.
USER
For changing an optional input module or
customising the pin assignments.
LAMP SELECT
DUAL
All lamps will light.
SINGLE
Selects a lamp with shorter duration of
use.
LAMP1
Selects the Lamp unit 1.
LAMP2
Selects the Lamp unit 2.
NOTE:
If, in the
SINGLE
,
LAMP1
or
LAMP2
mode, one lamp remains
off or the currently active lamp exceeds 2 000 hours of
cumulative operating time (when
HIGH
is selected as the
LAMP POWER
setting), the other lamp will light. If, in the
DUAL
mode, one lamp remains off or the currently active lamp
exceeds 2 000 hours of cumulative operating time (when
HIGH
is selected as the
LAMP POWER
setting), the other
lamp alone will light. However, if both lamps remain off or the
2 000 hours of cumulative operating time (when
HIGH
is
selected as the
LAMP POWER
setting) are exceeded, the
projector will enter the standby mode.
The colours of the items indicate the status.
Green: Current setting
Yellow: Current setting (when a lamp fails or fails to light)
Red: Lamp that has failed to light
White: Any other status.
If the projector is repeatedly used for short periods of time, the
lamps will need to be replaced more frequently.
LAMP RELAY
OFF
Deactive
00:00
-
23:00
1 hour interval from
00:00
to
23:00
NOTE:
Only when
DUAL
or
SINGLE
is selected in
LAMP SELECT
,
LAMP RELAY
is available. If
LAMP1
or
LAMP2
is selected,
LAMP RELAY
function is not available.
LAMP SELECT
setting
Repeated operation
SINGLE
LAMP1
and
LAMP2
light alternately by the
set time, and the shorter duration of use
lamp will light first.
DUAL
After both lamps light for the set time, only
one lamp is turned off for 2 hours, then for
only the other lamp for next 2 hours. The
longer duration of use lamp will be turned off
first.
LAMP POWER
HIGH
Set when high brightness is necessary.
LOW
Set when high brightness is not
necessary.
NOTE:
When set to
LOW
, it is possible to reduce power consumption,
reduce operating noise and extend lamp service life.
STANDBY MODE
NORMAL
The electrical consumption in standby
mode is 10 W.
ECO
The electrical consumption in standby
mode is 0.5 W.
NOTE:
• With
ECO
setting,
NETWORK
function,
RS-232C
output and
some of
RS-232C
commands are not available. When switch
on the projector, projection will start about 10 seconds late.
RS-232C
(IN) BAUDRATE
Select
9600
,
19200
or
38400
.
(IN) PARITY
Select
NONE
,
EVEN
or
ODD
.
(OUT) BAUDRATE
Select
9600
,
19200
or
38400
.
(OUT) PARITY
Select
NONE
,
EVEN
or
ODD
.
RESPONSE(ID ALL)
Select
ON
or
OFF
.
GROUP
Select
A
to
Z
.
RESPONSE(ID GROUP)
Select
ON
or
OFF
.
REMOTE2 MODE
PIN1
GND
PIN2
POWER
H
NONE
PIN3 - PIN7
RGB1
H
RGB2
H
VIDEO
H
S-VIDEO
H
DVI-
D
H
BALLAST VERSION
H
REWIND ALL
FILTER
H
NONE
PIN8
SHUTTER
H
NONE
PIN9
ENABLE
H
DISABLE