Panasonic PTFW300NTU Lcd Projector - Page 47

TEMP, LAMP and FILTER Indicators, Managing the indicated problems

Page 47 highlights

TEMP, LAMP and FILTER Indicators Managing the indicated problems If a problem should occur with the projector, the TEMP, LAMP and/or FILTER indicators will inform you. Manage the indicated problems as follow. 1. Confirm the status of all indicators and projector, and switch off the projector in proper way. 2. Find out the cause of the problem by status of the TEMP, LAMP and/or FILTER indicators. 3. Follow the instruction for each indication below and solve the problem. 4. Turn on the projector in the correct way and confirm the indicator is not indicating a problem any longer. LAMP TEMP FILTER NOTE: • If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorized Service Center. J LAMP indicator Indicator Illuminating red Flashing red Problem Cause Remedy RUNTIME of STATUS in the PROJECTOR SETUP menu has reached 5 000 hours. LAMP circuit failure, abnormal function or lamp unit is damaged. Lamp unit will run out soon and needs to be replaced. The MAIN POWER is switched on again before the lamp unit is cooled enough. Lamp circuit failure, abnormal function. Lamp unit is damaged. Let the lamp unit cool See "Replacing the Lamp down and turn on the unit" on page 48. MAIN POWER after 90 seconds. Contact an Authorized Service Center. See "Replacing the Lamp unit" on page 48. J TEMP indicator Indicator Illuminating red while projecting and the alert will be displayed. Flashing red and power is turned off Problem The temperature inside and/or outside the projector is abnormally high. Cause Remedy The ventilation openings are covered. Remove the object(s) from the ventilation openings or clear around the projector. The room temperature is too high. Reinstall the projector in temperature controlled place. See page 58. The projector is located at high elevations (above 1 400 - 2 700 m). Turn on the projector*1 and set the HIGH ALTITUDE MODE to ON. See page 42. *1. The projector will perform only 2 minutes with OFF setting at high elevation. J FILTER indicator When the FILTER indicator is flashing green, the Auto Cleaning Filter (ACF) is normally rolling up. Indicator Illuminating red Flashing red Flashing orange Illuminating orange Problem Cause Remedy REMAINING FILTER has Detect no ACF or turned red. See page 41. abnormal ACF. The ACF cannot operate properly. REMAINING FILTER has turned yellow. See page 41. ACF has been run out. ACF is not attached or the attached ACF is dysfunctional. Foreign object is blocking the ACF operation. ACF is running out. See "Replacing the Auto Cleaning Filter (ACF)" on page 49. Remove the foreign Attach the ACF or replace object or contact an to new ACF. Authorized Service Center. Prepare the ACF for replacement. Maintenance ENGLISH - 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

E
NGLISH - 47
Maintenance
TEMP, LAMP and FILTER Indicators
If a problem should occur with the projector, the
TEMP
,
LAMP
and/or
FILTER
indicators will inform you. Manage the indicated problems as
follow.
1.
Confirm the status of all indicators and projector, and switch off the
projector in proper way.
2.
Find out the cause of the problem by status of the
TEMP
,
LAMP
and/or
FILTER
indicators.
3.
Follow the instruction for each indication below and solve the
problem.
4.
Turn on the projector in the correct way and confirm the indicator is
not indicating a problem any longer.
LAMP indicator
TEMP indicator
FILTER indicator
When the
FILTER
indicator is flashing green, the Auto Cleaning Filter (ACF) is normally rolling up.
Managing the indicated problems
NOTE:
If no problem is found or the problem remains, do not turn on the projector. Instead contact an Authorized Service Center.
Indicator
Illuminating red
Flashing red
Problem
RUNTIME
of
STATUS
in
the
PROJECTOR
SETUP
menu
has
reached 5 000 hours.
LAMP
circuit failure, abnormal function or lamp unit is damaged.
Cause
Lamp unit will run out
soon and needs to be
replaced.
The
MAIN POWER
is
switched on again before
the lamp unit is cooled
enough.
Lamp circuit failure,
abnormal function.
Lamp unit is damaged.
Remedy
See “Replacing the Lamp
unit” on page 48.
Let the lamp unit cool
down and turn on the
MAIN POWER
after
90 seconds.
Contact an Authorized
Service Center.
See “Replacing the Lamp
unit” on page 48.
Indicator
Illuminating red while projecting and the alert will be displayed.
Flashing red and power is turned off
Problem
The temperature inside and/or outside the projector is abnormally high.
Cause
The ventilation openings are
covered.
The room temperature is too high.
The projector is located at high
elevations (above 1 400 - 2 700 m).
Remedy
Remove the object(s) from the
ventilation openings or clear
around the projector.
Reinstall the projector in
temperature controlled place. See
page 58.
Turn on the projector
*1
and set the
HIGH ALTITUDE MODE
to
ON
.
See page 42.
*1.
The projector will perform only 2 minutes with OFF setting at high elevation.
Indicator
Illuminating red
Flashing red
Flashing orange
Illuminating orange
Problem
REMAINING FILTER
has
turned red. See page 41.
Detect no ACF or
abnormal ACF.
The ACF cannot operate
properly.
REMAINING FILTER
has
turned yellow. See
page 41.
Cause
ACF has been run out.
ACF is not attached or the
attached ACF is
dysfunctional.
Foreign object is blocking
the ACF operation.
ACF is running out.
Remedy
See “Replacing the Auto
Cleaning Filter (ACF)” on
page 49.
Attach the ACF or replace
to new ACF.
Remove the foreign
object or contact an
Authorized Service
Center.
Prepare the ACF for
replacement.
LAMP
FILTER
TEMP