Ref. No 9 Procedure 3040819 How to remove the tonearm and PU fixing plate 1. Unsolder the 5 PU lead wires from the phono terminal. 2. Remove the setscrew(' and spring. 3. To remove the tonearm, remove the 2 setscrews (0 0). 4. To remove the PU fixing plate, remove the 2 setscrews (0, 0). " PU lead wiring method White L channel (+) terminal Blue L channel (-) terminal Red R channel (+) terminal Green R channel (-) terminal Black Ground terminal Spring 'PU fixing plate PU lead wires Ref. No 10 How to remove the cueing cam Procedure 30408110 1. Push the pin with a driver. 2. Remove the pin and spring. 3. Remove the cueing cam. Note: If the cueing time of the tonearm becomes too short, or if the cueing cam is replaced, apply silicon oil (Part No. SZZOL11) according to the following procedure. 1. Remove the cueing cam. 2. Apply silicon oil to the cueing cam and oil tank. Pin - Cueing cam -- Apply silicon oil Ref. No 11 Procedure 3 0 4 0 11 How to remove the turntable drive motor 1. Unsolder the terminal (FC101). 2. Remove the motor from cabinet. Motor Remove in the direction of the arrow. - 5- Caution for fitting (Flat cable) • The white side of the flat cable goes to the 0t of the FC101 terminal.