Panasonic WVCU360C WVCU360C User Guide - Page 14

DATA Port Connection (PS • Data), Controller end - wv cu360c can t move camera

Page 14 highlights

Example 2 shows 4 Data Multiplex Units connected with 16 combination cameras, and 4 System Controllers. 4 cameras can be connected to one Data Multiplex Unit Channel 1 Channel 2 Channel 4 Channel 13 Channel 14 Channel 16 WJ-MP204C Up to 4 Data Multiplex Units Unit address 1 Data Multiplex Unit WJ-MP204C Unit address 2 Data Multiplex Unit WJ-MP204 Unit address 4 Data Multiplex Unit WJ-MP204 Controller No. 1 360 System Controller WV-CU UP L R DOWN WV-CU360C Controller No. 2 Controller No. 4 360 System Controller WV-CU UP L R DOWN 360 System Controller WV-CU UP L R DOWN Up to 4 System Controllers See page 16 for MODE switch and CONTROLLER NO. switch settings. q DATA Port Connection (PS •Data) Data ports are connected with RS-485 cables among devices using the PS •Data protocol as follows. Notes: When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485 communication. • Internal Diagram No. Data Flow Name No. 1 1 - 2 WJ-MP204C ← WV-CU360C GND 1 Controller end TX(B) 2 1 3 WJ-MP204C ← WV-CU360C TX(A) 3 4 WJ-MP204C → WV-CU360C RX(B) 4 6 5 WJ-MP204C → WV-CU360C RX(A) 5 6 6 - GND 6 TX (B) TX (A) RX (B) RX (A) • Basic Connection Data Multiplex Unit WJ-MP204C System Controller WV-CU360C 14 DATA Termination: ON RS-485 Cable DATA Termination: ON

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77

14
DATA Port Connection (PS
Data)
Data ports are connected with RS-485 cables among devices using the PS
Data protocol as follows.
Notes:
When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485
communication.
Internal Diagram
Basic Connection
Example 2
shows 4 Data Multiplex Units connected with 16 combination cameras, and 4 System Controllers.
System Controller
WV
-
CU
360
System Controller
WV
-
CU
360
System Controller
WV
-
CU
360
Data Multiplex Unit WJ-MP204C
Data Multiplex Unit WJ-MP204
Data Multiplex Unit WJ-MP204
WJ-MP204C
WV-CU360C
4 cameras can be connected to one Data Multiplex Unit
Up to 4 Data Multiplex Units
Up to 4 System Controllers
Channel 1
Channel 2
Channel 4
Channel 13
Channel 14
Channel 16
Unit
address 1
Controller
No. 1
Controller No. 2
Controller No. 4
Unit
address 2
Unit
address 4
See page 16 for MODE switch and
CONTROLLER NO. switch settings.
DATA
Data Multiplex Unit
WJ-MP204C
System Controller
WV-CU360C
DATA
RS-485 Cable
Termination:
ON
Termination:
ON
Data Flow
WJ-MP204C
WV-CU360C
WJ-MP204C
WV-CU360C
WJ-MP204C
WV-CU360C
WJ-MP204C
WV-CU360C
1
6
1
6
No.
No.
1
1
2
2
3
3
4
4
5
5
6
6
Name
GND
TX(B)
TX(A)
RX(B)
RX(A)
GND
Controller end
TX (B)
TX (A)
RX (A)
RX (B)