Panasonic WVCU360C WVCU360C User Guide - Page 19

Administrator Authorization, Baud Rate, Parity, Wait Time, Controller Unit-Group Address

Page 19 highlights

q Administrator Authorization 1. Press the CAM/SET button while [SEtUP] is displayed. The prompt appears. 2. Enter a password with the numeric buttons, then press the CAM/SET button. The default setting is [12345]. 3. [SPEED] appears when the right password is entered. If password entry failed, the menu returns to Notes: • We recommend that you register a new password different from "12345" in [SUSrP], and note down the registered password for future reference. • Powering up the controller while holding down numeric buttons 2, 4 and 5 simultaneously will reset the password to "12345". Remember that this procedure also resets all other menu parameters to the default settings. q Baud Rate In this menu, the communication speed (bps: bits per second) is selected. The communication speed should match that of the other units connected in the communication chain. 1. Display [SPEED] and press the CAM/SET button twice. 2. Select a parameter entering a bracket-enclosed number, e.g., (3), moving the joystick right and left, or pressing the [+] and [-] button. The default setting is 19 200 bps. (1) 2 400: 2 400 bps (2) 4 800: 4 800 bps (3) 9 600: 9 600 bps (4) 19 200: 19 200 bps Note: Selecting a slower rate (e.g., 2 400 bps) will delay the response time (e.g., the time until an activated alarm is reset). 3. Press the CAM/SET button to validate the selection. 4. Press the ESC button to go back to the previous menu. q Parity In this menu, the parity check mode is selected. 1. Display [PrtY] and press the CAM/SET button twice. 2. Select a parameter with the joystick. The default setting is None. n: None E: Even parity 3. Press the CAM/SET button to validate the selection. 4. Press the ESC button to go back to the previous menu. q Wait Time In this menu a wait time is selected. The controller will retransmit data when there is no response during the specified wait time. 1. Display [LJAit] and press the CAM/SET button twice. 2. Select a parameter with the joystick. The default setting is Off. (1) OFF: Off, no retransmission of data (2) 100: 100 ms (3) 200: 200 ms (4) 400: 400 ms (5) 500: 500 ms (6) 1 000: 1 s 3. Press the CAM/SET button to validate the selection. 4. Press the ESC button to go back to the previous menu. The following two menus should be maintained in the default condition. q Controller Unit-Group Address [CU-gr] appears on the Setup menu, but leave the default as it is. q System Unit-Group Address [SU-gr] appears on the Setup menu, but leave the default as it is. 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77

19
Administrator Authorization
1. Press the CAM/SET button while [SEtUP] is displayed.
The [- - - - -] prompt appears.
2. Enter a password with the numeric buttons, then press
the CAM/SET button.
The default setting is [12345].
3.
[SPEED] appears when the right password is entered. If
password entry failed, the menu returns to [- - - - -].
Notes:
• We recommend that you register a new password dif-
ferent from “12345” in [SUSrP], and note down the reg-
istered password for future reference.
• Powering up the controller while holding down numeric
buttons 2, 4 and 5 simultaneously will reset the pass-
word to “12345”. Remember that this procedure also
resets all other menu parameters to the default settings.
Baud Rate
In this menu, the communication speed (bps: bits per sec-
ond) is selected.
The communication speed should match
that of the other units connected in the communication
chain.
1.
Display [SPEED] and press the CAM/SET button twice.
2. Select a parameter entering a bracket-enclosed num-
ber, e.g., (3), moving the joystick right and left, or
pressing the [+] and [–] button.
The default setting is 19 200 bps.
(1) 2 400:
2 400 bps
(2) 4 800:
4 800 bps
(3) 9 600:
9 600 bps
(4) 19 200:
19 200 bps
Note:
Selecting a slower rate (e.g., 2 400 bps) will
delay the response time (e.g., the time until an acti-
vated alarm is reset).
3.
Press the CAM/SET button to validate the selection.
4.
Press the ESC button to go back to the previous menu.
Parity
In this menu, the parity check mode is selected.
1.
Display [PrtY] and press the CAM/SET button twice.
2.
Select a parameter with the joystick.
The default setting is None.
n:
None
E:
Even parity
3.
Press the CAM/SET button to validate the selection.
4.
Press the ESC button to go back to the previous menu.
Wait Time
In this menu a wait time is selected. The controller will
retransmit data when there is no response during the speci-
fied wait time.
1.
Display [LJAit] and press the CAM/SET button twice.
2.
Select a parameter with the joystick.
The default setting is Off.
(1) OFF:
Off, no retransmission of data
(2) 100:
100 ms
(3) 200:
200 ms
(4) 400:
400 ms
(5) 500:
500 ms
(6) 1 000:
1 s
3.
Press the CAM/SET button to validate the selection.
4.
Press the ESC button to go back to the previous menu.
The following two menus should be maintained in the
default condition.
Controller Unit-Group Address
[CU-gr] appears on the Setup menu, but leave the
default as it is.
System Unit-Group Address
[SU-gr] appears on the Setup menu, but leave the
default as it is.