Pentair iChlor Salt Chlorine Generator iChlorManual - Page 19
Installation - system manual
View all Pentair iChlor Salt Chlorine Generator manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
15 INSTALLATION This section describes how to install the iChlor® SCG into the pool plumbing system. Also, included are connection instructions for IntelliTouch®, EasyTouch® and SunTouch® Control Systems. Before installing, review the iChlor kit contents and required tools. Note: For Power Center installation instructions, see the "Power Center Installation Guide" (P/N 520590). Note: Salt is not provided. For details about the type of salt to use, see "What Type of Salt to Use," on page 11. Note: A TIME CLOCK must be wired to the load side if the iChlor SCG is used in "stand alone" mode without an automation control system. Kit Contents • One iChlor SCG cell • Two (2) cell unions with two (2) o-rings • One iChlor adapter (to retrofit on existing iChlor SCG installations). • Installation and User's Guide (this manual) • Cut-out template Required Tools • Tape measure • Phillips and flathead screwdriver • Pliers • Hacksaw • An NSF approved all purpose PVC/CPVC/ABS cleaner primer • An NSF approved all purpose PVC/CPVC/ABS cement RISK OF ELECTRIC SHOCK, WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before attempting installation or service, ensure that all power to the circuit supplying power to the system is disconnected/turned off at the circuit breaker. It is recommended, but not mandatory that the iChlor Power Center be connected to a circuit protected by a ground fault circuit-interrupter (GFCI). When using electrical products, basic precautions should always be followed, including the following: • Grounding (earth bonding) is required. The unit should be installed by a qualified service person and grounded. • Install to allow access to cell buttons and power center. • Read Safety Precautions and Important Instructions (page i and ii). Before attempting any electrical wiring, be sure to read and follow Safety Instructions. Wiring should only be performed by a qualified professional. • Install the iChlor unit a minimum of three (3) feet away from the heater outlet. • Pipe couplings: Schedule 80, maximum pressure 50 psi at 70° F (21° C). • Operate unit with minimum flow of 20 gpm. For high flow applications (higher than 80 gpm), use a bypass loop (see page 5) for best flow sensing. • Provide at least 12"-18" of straight pipe in front of the cell inlet. iCHLOR® Salt Chlorine Generator Installation and User's Guide