3 Power Center The iChlor® Salt Chlorine Generator power center converts AC electrical current to a low-voltage DC electrical current which is required by the cell. The power supply should be connected with the pool circulation pump electrical source so that the iChlor only operates when the pool pump is on. The Power Center should be mounted vertically on the wall up to fifteen (15) feet away from the iChlor. The Power Center contains a transformer, fuse, connector to the cell and the AC electrical current wiring configuration with the DC electrical current output cable to the iChlor. A fuse is mounted on the circuit board inside the enclosure for additional protection. There are no other controls or lights on the Power Center. For information about installing and proper use of the Power Center, see the "Power Center Installation Guide," (P/N 520590). CHLORINE GAS BUILDUP CAN OCCUR WITH IMPROPER WIRING: To reduce the risk of personal injury the iChlor SCG Power Center must be installed on an automation filter pump relay wired to the load side of the time clock, electronically controlled switch, or relay load side, so that it will receive power only when the pool pump is on. Otherwise, dangerous chlorine gas buildup can occur. The iChlor SCG should never be energized when the pool pump is OFF and water is not flowing through the unit. iChlor SCG Power Center (Model PC 100) Before plugging or unplugging the iChlor SCG to the Power Center, first switch off the AC power to the Power Center. iChlor 15 Power Pack The iChlor 15 Power Pack converts AC electrical current to a low-voltage DC electrical current which is required by the cell. The Power Pack should be connected with the pool circulation pump electrical source so that the iChlor only operates when the pool pump is on. A 15 ft. cord connected to the iChlor 15 unit plugs into the Power Pack which plugs directly into a 110VAC outlet. The Power Pack can be mounted vertically on the wall up to fifteen (15) feet away from the iChlor. The Power Pack contains a transformer, fuse (1.5 AMP 250 V, 3 AG), connector to the cell and the AC electrical cord with plug. There are no other controls or lights on the Power Pack. The Power Pack must be connected to a GFCI protected outlet. CHLORINE GAS BUILDUP CAN OCCUR WITH IMPROPER WIRING: To reduce the risk of personal injury the iChlor SCG Power Center must be installed on an automation filter pump relay and wired to the load side of the time clock, electronically controlled switch, or relay load side, so that it will receive power only when the pool pump is on. Otherwise, dangerous chlorine gas buildup can occur. The iChlor SCG should never be energized when the pool pump is OFF and water is not flowing through the unit. iChlor 15 External Power Pack First switch OFF AC power to the Power Pack before plugging in or unplugging the iChlor 15. iCHLOR® Salt Chlorine Generator Installation and User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

3
iCHLOR® Salt Chlorine Generator Installation and User’s Guide
Power Center
The iChlor
®
Salt Chlorine Generator power center converts AC electrical current to a low-voltage DC electrical current
which is required by the cell. The power supply should be connected with the pool circulation pump electrical source
so that the iChlor only operates when the pool pump is on. The Power Center should be mounted vertically on the
wall up to fifteen (15) feet away from the iChlor. The Power Center contains a transformer, fuse, connector to the cell
and the AC electrical current wiring configuration with the DC electrical current output cable to the iChlor. A fuse is
mounted on the circuit board inside the enclosure for additional protection. There are no other controls or lights on the
Power Center. For information about installing and proper use of the Power Center, see the “Power Center Installation
Guide,” (P/N 520590).
iChlor SCG Power Center
(Model PC 100)
iChlor 15 External
Power Pack
iChlor 15 Power Pack
The iChlor 15 Power Pack converts AC electrical current to a low-voltage DC electrical current which is required by
the cell. The Power Pack should be connected with the pool circulation pump electrical source so that the iChlor only
operates when the pool pump is on. A 15 ft. cord connected to the iChlor 15 unit plugs into the Power Pack which
plugs directly into a 110VAC outlet. The Power Pack can be mounted vertically on the wall up to fifteen (15) feet away
from the iChlor. The Power Pack contains a transformer, fuse (1.5 AMP 250 V, 3 AG), connector to the cell and the AC
electrical cord with plug. There are no other controls or lights on the Power Pack. The Power Pack must be connected
to a GFCI protected outlet.
Before plugging
or unplugging the
iChlor SCG to the Power Center, first
switch off the AC power to the Power
Center.
CHLORINE GAS BUILDUP
CAN OCCUR WITH
IMPROPER WIRING:
To reduce the risk of
personal injury the iChlor SCG Power Center
must be installed on an automation filter pump
relay wired to the load side of the time clock,
electronically controlled switch, or relay load
side, so that it will receive power only when the
pool pump is on. Otherwise, dangerous chlorine
gas buildup can occur. The iChlor SCG should
never be energized when the pool pump is OFF
and water is not flowing through the unit.
CHLORINE GAS BUILDUP
CAN OCCUR WITH IMPROPER
WIRING:
To reduce the risk of personal injury the
iChlor SCG Power Center must be installed on an
automation filter pump relay and wired to the load
side of the time clock, electronically controlled
switch, or relay load side, so that it will receive
power only when the pool pump is on. Otherwise,
dangerous chlorine gas buildup can occur. The iChlor
SCG should never be energized when the pool pump
is OFF and water is not flowing through the unit.
First switch OFF
AC power to the
Power Pack before plugging in or
unplugging the iChlor 15.