SYMBOLS SAFETY LABELS The following labels are found on the generator. For your safety, please study and understand all of the labels before starting the generator. If any of the labels come off the unit or become hard to read, contact an authorized service center for replacement. FUEL WARNING DO NOT SMOKE when filling with gasoline. Do not over fill. Full level is 1 inch below the top of the fuel neck. Stop the engine two minutes before refueling to avoid the heat from the muffler igniting fuel vapors. $!.'%2 You will be KILLED or SERIOUSLY HURT if you do not follow the Owner's Manual instructions. Do not expose to rain or use in damp locations. Risk of Fire. Do not add fuel while the product is operating. Exhaust contains poisonous carbon monoxide gas that can cause unconsciousness or DEATH. Operate in well ventilated, outdoor areas away from open windows or doors. Generator is a potential source of electric shock. Do not expose to moisture, rain, or snow. Ground the system. Do not operate with wet hands or feet. HOT MUFFLER WARNING Do not touch the muffler or aluminum cylinder of the engine. They are very HOT and will cause severe burns. Don't put any flammable or combustible materials in the direct path of the exhaust. #HECKªFORªANYª FUELªOVERFLOWªOR LEAKING 3TOPªTHEªENGINE BEFOREªREFUELING WARNING HOT MUFFLER DO NOT TOUCH VENTILATION WARNING Do not use the generator in an enclosed area or near open windows, vents, or doors. Fumes from the unit can kill. ENGINE OIL WARNING You must add oil before the first operation of the generator. The oil reservoir capacity is 1.2 quarts. Always check the oil level before each operation. The oil level should always register on the dipstick. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

7
SYMBOLS
SAFETY LABELS
The following labels are found on the generator. For your
safety, please study and understand all of the labels
before starting the generator.
If any of the labels come off the unit or become hard to
read, contact an authorized service center for replacement.
FUEL WARNING
DO NOT SMOKE
when filling with gasoline. Do not over
fill. Full level is 1 inch below the top of the fuel neck.
Stop the engine two minutes before refueling to avoid
the heat from the muffler igniting fuel vapors.
ENGINE OIL WARNING
You must add oil before the first operation of the generator.
The oil reservoir capacity is 1.2 quarts. Always check the
oil level before each operation. The oil level should always
register on the dipstick.
HOT MUFFLER WARNING
Do not touch the muffler or aluminum cylinder of the
engine. They are very HOT and will cause severe burns.
Don’t put any flammable or combustible materials in the
direct path of the exhaust.
VENTILATION WARNING
Do not use the generator in an enclosed area or near
open windows, vents, or doors. Fumes from the unit can
kill.
You will be KILLED or SERIOUSLY HURT
if you do not follow the Owner’s Manual
instructions.
Do not expose to rain or use in damp
locations.
Risk of Fire. Do not add fuel while the
product is operating.
Exhaust contains poisonous carbon monox-
ide gas that can cause unconsciousness or
DEATH. Operate in well ventilated, outdoor
areas away from open windows or doors.
Generator is a potential source of electric
shock. Do not expose to moisture, rain, or
snow. Ground the system. Do not operate
with wet hands or feet.
WARNING
HOT
MUFFLER
DO NOT
TOUCH