ProForm 395 E Elliptical English Manual - Page 20
Maintenance And Troubleshooting - batteries
View all ProForm 395 E Elliptical manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
MAINTENANCE AND TROUBLESHOOTING Inspect and tighten all parts of the elliptical regularly. Replace any worn parts immediately. Note: For clarity, the pedal disc is shown removed in the drawing below. To clean the elliptical, use a damp cloth and a small amount of mild soap. IMPORTANT: To avoid damage to the console, keep liquids away from the console and keep the console out of direct sunlight. Next, locate the Reed Switch (58). Loosen, but do not remove, the M4 x 16mm Screw (53). CONSOLE TROUBLESHOOTING If the console display becomes dim, replace all the batteries at the same time; most console problems are the result of low batteries. See assembly step 7 on page 9 for replacement instructions. If the console does not display your heart rate when you use the handgrip heart rate monitor, see step 5 on page 18. 65 53 41 58 HOW TO ADJUST THE REED SWITCH If the console does not display correct feedback, the reed switch should be adjusted. To adjust the reed switch, you must first remove the Shield Cover (37). Using a flat screwdriver, release the tabs along the sides of the Shield Cover and then remove the Shield Cover. 37 Next, rotate the Pulley (65) until a Magnet (41) is aligned with the Reed Switch (58). Slide the Reed Switch slightly toward or away from the Magnet. Then, retighten the M4 x 16mm Screw (53). Rotate the Pulley (65) for a moment. Repeat these actions until the console displays correct feedback. When the reed switch is correctly adjusted, reattach the shield cover. 20