ProForm 545 Uk Manual - Page 12

Troubleshooting

Page 12 highlights

TROUBLESHOOTING Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please call our Customer Service Department. PROBLEM: The power does not turn on SOLUTION: a. Make sure that the power cord is plugged into a properly earthed outlet. (See on page 7.) If an extension cord is needed, use only a 3-conductor, 1 mm2 (14-gauge) cord that is no longer than 1.5 m (5 ft.). b. After the power cord has been plugged in, make sure that the key is fully inserted into the console. c. Check the circuit breaker located on the treadmill frame near the power cord. If the switch protrudes as shown, the circuit breaker has tripped. To reset the circuit breaker, wait for five minutes and then press the switch back in. PROBLEM: The power turns off during use c Tripped Tripped Reset Reset SOLUTION: a. Check the circuit breaker located on the treadmill frame near the power cord (see the drawing above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in. b. Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for five minutes, and then plug it back in. c. Remove the key from the console. Reinsert the key fully into the console. d. If the treadmill still will not run, please call our Customer Service Department. PROBLEM: The displays of the console do not function properly SOLUTION: a. UNPLUG THE POWER CORD. Check the batteries in the console. If the batteries need to be replaced, see BATTERY INSTALLATION on page 8. Most problems are the result of drained batteries. b. Remove the key from the console and UNPLUG THE POWER CORD. Remove the screws from the hood, and carefully remove the hood. Locate the Reed Switch (44) and the Magnet (45) on the left side of the Pulley (50). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that the gap between the Magnet and the Reed Switch is about 3 mm (1/8"). If necessary, loosen the Screw (33) and move the Reed Switch slightly. Retighten the Screw. Re-attach the hood, and run the treadmill for a few minutes to check for a correct speed reading. b 3 mm 44 33 Top View 50 45 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

TROUBLESHOOTING
Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and
follow the steps listed. If further assistance is needed, please call our Customer Service Department.
PROBLEM:
The power does not turn on
SOLUTION:
a.
Make sure that the power cord is plugged into a properly earthed outlet. (See on page 7.) If an
extension cord is needed, use only a 3-conductor, 1 mm
2
(14-gauge) cord that is no longer than
1.5 m (5 ft.).
b.
After the power cord has been plugged in, make sure that the key is fully inserted into the console.
c.
Check the circuit breaker located on the treadmill
frame near the power cord. If the switch protrudes
as shown, the circuit breaker has tripped. To reset
the circuit breaker, wait for five minutes and then
press the switch back in.
PROBLEM:
The power turns off during use
SOLUTION:
a.
Check the circuit breaker located on the treadmill frame near the power cord (see the drawing
above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.
b.
Make sure that the power cord is plugged in. If the power cord is plugged in, unplug it, wait for
five minutes, and then plug it back in.
c.
Remove the key from the console. Reinsert the key fully into the console.
d.
If the treadmill still will not run, please call our Customer Service Department.
PROBLEM:
The displays of the console do not function properly
SOLUTION:
a.
UNPLUG THE POWER CORD.
Check the batteries in the console. If the batteries need to be re-
placed, see BATTERY INSTALLATION on page 8. Most problems are the result of drained batteries.
b.
Remove the key from the console and
UNPLUG THE POWER CORD.
Remove the screws from
the hood, and carefully remove the hood.
Locate the Reed Switch (44) and the Magnet (45) on
the left side of the Pulley (50). Turn the Pulley until
the Magnet is aligned with the Reed Switch.
Make
sure that the gap between the Magnet and the
Reed Switch is about 3 mm (1/8”).
If necessary,
loosen the Screw (33) and move the Reed Switch
slightly. Retighten the Screw. Re-attach the hood, and
run the treadmill for a few minutes to check for a cor-
rect speed reading.
Tripped
Reset
Tripped
Reset
c
45
44
33
Top
View
3 mm
50
12
b