Pyle PT4001X PT1201X Manual 1 - Page 4
Stereo Operation, Mono Bridged Operation, Mono Operation
![]() |
View all Pyle PT4001X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
STEREO OPERATION SWITCH IN "STEREO" POSITION EQ OR MIXER use XLR/6.35 mm combo jacks EQ OR MIXER use RCA jacks CH 2 CH 1 Stereo or Mono Inputs Your Pyle Pro amplifier can be operated in Stereo, Mono or Bridged mode, depending on the input source. If the input signal is mono, slide the Stereo/Mono/Bridged selector switch to MONO and the signal will be routed through both channels. If you wish to run the amplifier in bridged output mode, slide the switch to Bridged. Speaker connections You can connect 4 Ohm, 8 Ohm or 16 Ohm speakers to Channel 1 and/or Channel 2 of the amplifier. If you connect two pairs of speakers, be sure to follow these guidelines: • Speakers which are connected to the same channel are part of a pair, and must be of the same impedance. • Speakers connected to different channels are NOT part of a pair, and can be of different impedances. 1. Prepare the speaker wire by removing about 1 inch of insulation from the end of the speaker wire you intend to connect to the amplifier. Then twist the exposed wire to secure all the wire strands. NOTE: Use 16-gauge speaker wire for lengths up to25 feet; 14-gauge wire for lengths over 25 feet. It is recommended that you use the shortest length of wire possible. 2. Connect the speaker wires to the speaker's positive and negative terminals. NOTE: Most speaker terminals are either color-coded or have a mark that indicates the terminal's polarity. Usually positive terminals are red or have a plus symbol (+), and negative terminals are black or have a minus symbol (-). 3. Connect the speaker wires to the amplifier's left and right speaker terminals according to the terminal color polarity. PYLE PRO PT-1201X/1601X/2001X/4001X Amplifier Owner's Manual - 4 STEREO SIGNAL SOURCE CH 2 CH 1 STEREO SIGNAL SOURCE CH 2 CH 1 ~ AC 120V 60HZ OUTPUTS CH-2 CH-1 BRIDGE GND GROUND LIFT GROUND LIFT BALANCED INPUTS 21 3 CAUTION: DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE. CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH SAME TYPE FUSE. CAUTION: TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE INPUTS CH-2 CH-1 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CH-2 CH-1 MONO STEREO BRIDGE STEREO SIGNAL SOURCE CAUTION! Do not use balanced and unbalanced inputs simultaneously!! HOT(+) COLD(-) GND(+) HOT(+) COLD(-) GND(+) HOT(+) COLD(-) GND(+) MONO OPERATION SWITCH IN "MONO" POSITION CH 2 CH 1 MONO SIGNAL SOURCE USE CHANNEL 1 INPUT ONLY Bridged Mode Operation This amplifier can operate in a mono bridged output mode, if your speakers can handle the following power output levels: As shown in the diagram below, connect the speaker's positive (+) to the amplifier's red speakers left (1/2) terminals and negative (-) to red speakers right (1/2) terminals. The speaker right (+) on the amplifier is used as a negative (-) terminal for a bridged connection. NOTE: The extra amplifier output of 6.35mm phone jacks can not be used for the bridged connection. It can only be used in normal (non-bridged) operation as a stereo speaker output. MONO BRIDGED OPERATION SWITCH IN "BRIDGED" POSITION DO NOT USE BLACK TERMINALS CH 2 CH 1 USE CHANNEL 1 INPUT ONLY MONO SIGNAL SOURCE MONO SIGNAL SOURCE DO NOT USE BLACK TERMINALS USE CHANNEL 1 INPUT ONLY CH 2 CH 1 ~ AC 120V 60HZ OUTPUTS CH-2 CH-1 BRIDGE GND GROUND LIFT GROUND LIFT BALANCED INPUTS 21 3 CAUTION: DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE. CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH SAME TYPE FUSE. CAUTION: TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE INPUTS CH-2 CH-1 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CH-2 CH-1 MONO STEREO BRIDGE MONO SIGNAL SOURCE USE CHANNEL 1 INPUT ONLY CAUTION! Do not use balanced and unbalanced inputs simultaneously!! USE CHANNEL 1 INPUT ONLY MONO SIGNAL SOURCE DO NOT USE BLACK TERMINALS ~ AC 120V 60HZ OUTPUTS CH-2 CH-1 BRIDGE GND GROUND LIFT GROUND LIFT BALANCED INPUTS 21 3 CAUTION: DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE. CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH SAME TYPE FUSE. CAUTION: TO PREVENT ELECTRIC SHOCK DO NOT USE THIS (POLARIZED) PLUG WITH AN EXTENSION CORD RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE INPUTS CH-2 CH-1 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CH-2 CH-1 MONO STEREO BRIDGE MONO SIGNAL SOURCE USE CHANNEL 1 INPUT ONLY CAUTION! Do not use balanced and unbalanced inputs simultaneously!! 5 - PYLE PRO PT-1201X/1601X/2001X/4001X Amplifier Owner's Manual
![](/manual_guide/products/pyle-pt1201x-pt1201x-manual-1-6fd758f/4.png)