Pyle SLACHT108 Instruction Manual - Page 11

Common Failures and Diagnosis

Page 11 highlights

Common Failures and Diagnosis Intelligent Error Detection Error-detecting code Multi-functional defection E1 Error of the coil's temperature sensor E2 Error of indoor temperature sensor Anti-freezing protection: temperature of the coil is too low E4 and the whole A/C is o . When temperature excesses 8°C or 46.4°F, the protection is released and previous working state is recovered. FUSE PARAMETERS • Voltage: 250VAC • Current: 3.15A Troubleshooting In case of any of the following trouble, please contact professional maintenance personnel in time. TROUBLE The A/C doesn't work The A/C starts frequently CAUSE No display The display panel displays "FL" Time OFF function is started Direct sunlight Doors and windows keep open; there are lots of people or heat source in room Filter screen is very dirty SOLUTION Reset circuit breaker on AC cord Restart the A/C after power off and draining, then it will become normal The A/C can be restarted 3 minutes after being turning off. Draw the curtain Close doors and windows, remove heat source Clean or replace it Big noise of the A/C The compressor doesn't work Air inlet or air outlet is blocked The A/C is placed unevenly Its delay protection is started Remove the stem Place it at even and firm ground, avoid shaking Wait for 3min., turn on after temperature decreases Notice: When there is any abnormal to the A/C, turn it o and unplug, and then contact professional maintenance personnel. The above technical parameters are subject to change without notice. www.SereneLifeHome.com 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

www.SereneLifeHome.com
11
Common Failures and Diagnosis
Intelligent Error Detection
FUSE PARAMETERS
Voltage:
250VAC
Current:
3.15A
Troubleshooting
In case of any of the following trouble, please contact professional
maintenance personnel in time.
Notice:
When there is any abnormal to the A/C, turn it off and unplug, and
then contact professional maintenance personnel.
The above technical parameters are subject to change without notice.
Error-detecting code
Multi-functional defection
E1
Error of the coil’s temperature sensor
E2
Error of indoor temperature sensor
E4
Anti-freezing protection:
temperature of the coil is too low
and the whole A/C is off. When temperature excesses 8°C
or 46.4°F, the protection is released and previous working
state is recovered.
The A/C
do
e
s
n
t
work
No display
Reset circuit breaker on
AC cord
The
display panel d
i
s
p
l
a
ys
FL
Restart the
A/C
after
power
off
and
draining, then it will become
no
r
m
a
l
Time
OFF
function is
s
t
a
r
t
e
d
The A/C can be
restarted
3
m
i
nu
t
e
s
after being turning
o
ff
.
The A/C
s
t
a
r
t
s
f
r
e
qu
e
n
t
l
y
Direct
s
un
li
gh
t
Draw the
c
u
r
t
a
i
n
Doors and windows
keep
open;
there
are
lots of
p
e
op
l
e
or
heat source in
room
Close
doors and
windows,
remove
heat
source
Filter screen is very
d
i
r
t
y
Clean
or
replace
i
t
Air inlet
or
air outlet is
b
l
o
ck
e
d
Remove the
s
t
e
m
Big noise of
t
h
e
A/C
The A/C
is placed
un
e
v
e
n
l
y
Place
it
at
even and
firm
ground,
avoid
s
h
a
k
i
ng
The compressor
doesn’t
work
Its delay protection is
s
t
a
r
t
e
d
Wait
for
3min.,
turn
on
a
ft
e
r
temperature
decreases
TROUBLE
CAUSE
SOLUTION