Pyle SLACHT108 Instruction Manual - Page 11
Common Failures and Diagnosis
View all Pyle SLACHT108 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Common Failures and Diagnosis Intelligent Error Detection Error-detecting code Multi-functional defection E1 Error of the coil's temperature sensor E2 Error of indoor temperature sensor Anti-freezing protection: temperature of the coil is too low E4 and the whole A/C is o . When temperature excesses 8°C or 46.4°F, the protection is released and previous working state is recovered. FUSE PARAMETERS • Voltage: 250VAC • Current: 3.15A Troubleshooting In case of any of the following trouble, please contact professional maintenance personnel in time. TROUBLE The A/C doesn't work The A/C starts frequently CAUSE No display The display panel displays "FL" Time OFF function is started Direct sunlight Doors and windows keep open; there are lots of people or heat source in room Filter screen is very dirty SOLUTION Reset circuit breaker on AC cord Restart the A/C after power off and draining, then it will become normal The A/C can be restarted 3 minutes after being turning off. Draw the curtain Close doors and windows, remove heat source Clean or replace it Big noise of the A/C The compressor doesn't work Air inlet or air outlet is blocked The A/C is placed unevenly Its delay protection is started Remove the stem Place it at even and firm ground, avoid shaking Wait for 3min., turn on after temperature decreases Notice: When there is any abnormal to the A/C, turn it o and unplug, and then contact professional maintenance personnel. The above technical parameters are subject to change without notice. www.SereneLifeHome.com 11