Rheem H95 Outdoor Series Use and Care Manual - Page 38
Location, Requirements
View all Rheem H95 Outdoor Series manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
INSTALLATION INSTRUCTIONS Venting VentingforDirect-VentWaterHeater(cont.) The followingchartdetailstheminimaldimensionalinformationneededtodeterminetheproperlocationofthevent terminalfordirectventandoutdoortanklesswaterheaters.Seecorrespondingletterreferenceintheillustrationat left. Location U.S.Installation Requirements1 CanadianInstallation Requirements2 A=Clearanceabovegrade,veranda, porch,deck,orbalcony. 12in.(30cm) 12in.(30cm) B=Clearancetowindowordoorthatmay beopened. •6in.(15cm)forwaterheaterslessthanor equalto10,000Btuh(3kW). •9in.(23cm)forwaterheatersgreaterthan 10,000Btuh(3kW)andlessthanorequalto 50,000Btuh(15kW). •12in.(30cm)forwaterheatersgreaterthan 50,000Btuh(15kW). •6in.(15cm)forwaterheaterslessthanor equalto10,000Btuh(3kW). •12in.(30cm)forwaterheatersgreaterthan 10,000Btuh(3kW)andlessthanorequalto 100,000Btuh(30kW). •36in.(91cm)forwaterheatersgreaterthan 100,000Btuh(30kW). C=Clearancetopermanentlyclosed window. D=Verticalclearancetoventilatedsoffit locatedabovetheterminalwithina horizontaldistanceof2ft.(61cm) fromthecenterlineoftheterminal. E=Clearancetounventilatedsoffit. F=Clearancetooutsidecorner. G=Clearancetoinsidecorner. H=Clearancetoeachsideofcenterline extendedabovemeter/regulator assembly. 3ft.(91cm)withinaheightof15ft.(4,57m) abovethemeter/regulatorassembly. I=Clearancetoserviceregulatorvent outlet. 3ft.(91cm) J=Clearancetononmechanicalairsupply inlettothecombustionairinlettoany buildingorotherappliance. •6in.(15cm)forwaterheaterslessthanor equalto10,000Btuh(3kW). •9in.(23cm)forwaterheatersgreaterthan 10,000Btuh(3kW)andlessthanorequalto 50,000Btuh(15kW). •12in.(30cm)forwaterheatersgreaterthan 50,000Btuh(15kW). •6in.(15cm)forwaterheaterslessthanor equalto10,000Btuh(3kW). •12in.(30cm)forwaterheatersgreaterthan 10,000Btuh(3kW)andlessthanorequalto 100,000Btuh(30kW). •36in.(91cm)forwaterheatersgreaterthan 100,000Btuh(30kW). K=Clearancetomechanicalairsupply inlet. 3ft.(91cm)aboveifwithin10ft.(3m) horizontally. 6ft.(1,83m) L=Clearanceabovepavedsidewalkor paveddrivewaylocatedonpublic property. 7ft.(2,13m)† M=Clearanceunderveranda,porch,deck, orbalcony. 12in.(30cm)‡ 1 InaccordancewithcurrentANSIZ223.1/NFPA54NationalFuelGasCode. 2InaccordancewithcurrentCAN/CSAB149.1InstallationCodes. ForclearancesnotspecifiedinANSIZ223.1/NFPA54orCAN/CSAB149.1,oneofthefollowingshallbeindicated: a) Aminimumclearancevaluedeterminedbytestinginaccordancewithsection2.20,or b) Areferencetothefollowingfootnote:"Clearanceinaccordancewithlocalinstallationcodesandtherequirementsofthegassupplier." †Aventshallnotterminatedirectlyaboveasidewalkorpaveddrivewaythatislocatedbetweentwosingle-familydwellingsandservesboth dwellings. ‡Permittedonlyifveranda,porch,deck,orbalconyisfullyopenonaminimumoftwosidesbeneaththefloor. 38