Rheem Versa Spa Heaters Operating Instructions - Page 19

Fig. 19: Intermittent Ignition Devices, Fig. 20: 120V Wiring, Fig. 21: 240V Wiring

Page 19 highlights

240V ATMOSPHERIC HEATER Robertshaw Intermittent Ignition Device Honeywell Intermittent Ignition Device Fig. 19: Intermittent Ignition Devices SUPPLY SIDE HOT L1 BLACK HOT L2 RED GREEN BLACK RED GREEN HEATER 4 WIRES WHITE Fig. 21: 240V Wiring For 120 V input power to the unit, connect the black wire to the "L1", or hot leg, of the power supply. Connect the white wire to the "L2", or neutral leg, of the power supply. Attach the wire nut to the red wire. There should be no connection to the red wire for 120V operation. CAUTION: Heater must be electrically grounded and bonded in accordance with local codes, or, in the absence of local codes, with the latest edition of the National Electrical code, ANSI/NFPA 70 (Canada- Canadian Electrical Code, CSA C22.1, Part 1). 120V ATMOSPHERIC HEATER SUPPLY SIDE HOT L1 BLACK RETURN or NEUTRAL WHITE GROUND GREEN BLACK WHITE GREEN HEATER 4 WIRES NbeOsTuEpp: lIinepduftropmowtehre1tol2o0tahVde L(hpOeuaWmtepNr)(Os1i2xd0eH/2oE4fA0tTiVmE)eRshcoloucldk or switch. Connecting heater to continuous power source will allow "FLail" iBndications (service and pressure switch) when pump is not operating. WIRING DIAGRAM KEY H PINK CONNECTOR BLUE CONNECTOR RED Fig. 20: 120V Wiring For 240 V input power to the unit, connect the black wire to the "L1", or hot leg, of the power supply. Connect the red wire to the "L2", or second hot leg, of the power supply. Attach the wire nut to the white wire. There should be no connection to the white wire for 240V operation. S86 SPK S8600 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

19
Robertshaw Intermittent
Ignition Device
Honeywell Intermittent
Ignition Device
Fig. 19: Intermittent Ignition Devices
For 120 V input power to the unit, connect the black
wire to the “L1”, or hot leg, of the power supply.
Connect the white wire to the “L2”, or neutral leg, of the
power supply. Attach the wire nut to the red wire. There
should be no connection to the red wire for 120V oper-
ation.
For 240 V input power to the unit, connect the black
wire to the “L1”, or hot leg, of the power supply.
Connect the red wire to the “L2”, or second hot leg, of
the power supply. Attach the wire nut to the white wire.
There should be no connection to the white wire for
240V operation.
120V ATMOSPHERIC HEATER
SUPPLY
SIDE
RETURN
or
NEUTRAL
HEATER
4 WIRES
GROUND
L1
RED
BLACK
HOT
BLACK
GREEN
GREEN
WHITE
WHITE
Fig. 20: 120V Wiring
240V ATMOSPHERIC HEATER
HEATER
4 WIRES
L1
L2
RED
RED
BLACK
HOT
HOT
BLACK
GREEN
GREEN
WHITE
SUPPLY
SIDE
Fig. 21: 240V Wiring
NOTE:
Input power to the heater (120/240V) should
be supplied from the load (pump) side of time clock
or switch. Connecting heater to continuous power
source will allow "Fail" indications (service and
pressure switch) when pump is not operating.
SPK
WIRING DIAGRAM KEY
0
0
6
8
S
6
8
S
PINK CONNECTOR
BLUE CONNECTOR
CAUTION:
Heater must be electrically grounded
and bonded in accordance with local codes, or, in the
absence of local codes, with the latest edition of the
National Electrical code, ANSI/NFPA 70 (Canada-
Canadian Electrical Code, CSA C22.1, Part 1).