Ricoh P C200W Printer Languages and Interfaces Technical Reference - Page 24
Vertical Rectangle Size in PCL Units, Area Fill ID, Gray Scale Fills, Cross, Hatch Fills
View all Ricoh P C200W manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
Printer Control Language (PCL) emulation 24 Command / Parameters ESC*c#B Where: # = number of PCL units (0-32767). 0 is the factory default value. ESC*c#G Gray Scale Fills 0-White (default) 1-2-2% gray 3-10-10% gray 11-20-15% gray 21-35-30% gray 36-55-45% gray 56-80-70% gray 81-99-90% gray 100-100% gray (black) Cross‑Hatch Fills 1-Horizontal line 2-Vertical line 3-Diagonal line 4-Diagonal line 5-Square Grid 6-Diagonal Grid User-Defined Patterns Where: # = user‑defined pattern ID. ESC*c#P 0-Black fill (default) 1-White fill 2-Gray fill 3-Predefined cross-hatch pattern fill 4-User-defined pattern 5-Current pattern fill Function / Result Vertical Rectangle Size (in PCL Units) Specifies the rectangle height in PCL units. Note: The size of PCL Units is set by the Unit-of-Measure command. Area Fill ID Selects the pattern used to fill the rectangular area. Note: This command is also used to set the user-defined pattern ID. Fill Rectangular Area Fills a rectangular area defined by horizontal and vertical rectangle sizes with the selected pattern.