Ryobi RYi2300BTA Operation Manual - Page 14

Features - oil type

Page 14 highlights

FEATURES PRODUCT SPECIFICATIONS ENGINE Engine Type 80cc Overhead Valve (OHV) Spark Plug Torch E6RTC or equivalent Lubricant Fill Volume Approximately 12 oz Fuel Volume 1.2 gal. *Rated output determined by PGMA Standard G300 GENERATOR Rated Voltage 120V AC/5V DC Rated Amps 15A AC/2.1A DC Rated Output 1,800 W Starting Watts 2,300 W Rated Frequency 60 Hz KNOW YOUR GENERATOR See Figure 1. The safe use of this product requires an understanding of the information on the product and in this operator's manual as well as a knowledge of the project you are attempting. Before use of this product, familiarize yourself with all o­ perating features and safety rules. 120 V AC RECEPTACLES Your generator has two single phase, 60 Hz outlets that are 120 Volt AC, 20 Amp receptacles. These can be used for operating appropriate appliances, electrical lighting, tools, and motor loads. GROUND TERMINAL The ground terminal is used to assist in properly grounding the generator to help protect against electrical shock. Consult with a qualified local electrician for grounding requirements in your area. LOW OIL SHUT DOWN PROTECTOR The low oil sensor causes the engine to stop if the level of lubricant in the crankcase is insufficient. OIL CAP/DIPSTICK Remove the oil fill cap to check and add lubricant to the generator when necessary. AIR FILTER The air filter help to limit the amount of dirt and dust drawn into the unit during operation. AUTO IDLE BUTTON The auto idle button is used to control the speed of the engine and conserve fuel. When Auto Idle is on and no appliances are connected to the unit, the engine will idle. If an appliance is added, the engine speed will increase to power the item. If the appliance is removed, the engine will return to idle. CARRY HANDLES The generator is equipped with three carry handles for easy transport. The handles should be used to carry the generator. EASY START DIAL The Easy Start dial is used when starting, stopping, and running the engine. It also controls the choke and the fuel valve. FUEL TANK The fuel tank has a capacity of 1.2 gallons. GENCONTROL™ WITH BLUETOOTH® The GENControl™ monitoring system with Bluetooth® tracks fuel level, runtime, auto idle status and load. PARALLEL KIT TERMINALS The non-polarized parallel kit terminals are used with a parallel kit (sold separately) that will allow generators to be linked together to increase output. NOTICE: Do not disconnect cables while the generator is running. The generator or the load may be damaged. NOTE: Read and understand the parallel kit's instructions prior to use. Kit is for usage with this unit only. RECOIL STARTER The recoil starter is used (along with the Easy Start dial) to start the generator's engine. RESET BUTTON The reset button is used to restore power if an overload occurs. To restore power, remove the last electrical load added, then press the reset button. RETRACTABLE HANDLE The generator is equipped with a retractable handle that can be adjusted for storage and transportation. USB PORTS The two 5 Volt, 2.1 Amp USB-dedicated charging ports will charge most USB-compatible devices. 10 - English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

10 — English
FEATURES
KNOW YOUR GENERATOR
See Figure 1.
The safe use of this product requires an understanding of the
information on the product and in this operator’s manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all
operating
features and safety rules.
120 V AC RECEPTACLES
Your generator has two single phase, 60 Hz outlets that
are
120 Volt AC, 20 Amp receptacles. These can be used for
operating appropriate appliances, electrical lighting, tools,
and motor loads.
AIR FILTER
The air filter help to limit the amount of dirt and dust drawn
into the unit during operation.
AUTO IDLE BUTTON
The auto idle button is used to control the speed of the
engine and conserve fuel. When Auto Idle is on and no
appliances are connected to the unit, the engine will idle.
If an appliance is added, the engine speed will increase to
power the item. If the appliance is removed, the engine will
return to idle.
CARRY HANDLES
The generator is equipped with three carry handles for
easy transport. The handles should be used to carry the
generator.
EASY START DIAL
The Easy Start dial is used when starting, stopping, and run-
ning the engine. It also controls the choke and the fuel valve.
FUEL TANK
The fuel tank has a capacity of 1.2 gallons.
GENCONTROL™ WITH BLUETOOTH
®
The GENControl™ monitoring system with
Bluetooth
®
tracks fuel level, runtime, auto idle status and load.
GROUND TERMINAL
The ground terminal is used to assist in properly grounding
the generator to help protect against electrical shock. Con-
sult with a qualified local electrician for grounding require-
ments in your area.
LOW OIL SHUT DOWN PROTECTOR
The low oil sensor causes the engine to stop if the level of
lubricant in the crankcase is insufficient.
OIL CAP/DIPSTICK
Remove the oil fill cap to check and add lubricant to the
generator when necessary.
PARALLEL KIT TERMINALS
The non-polarized parallel kit terminals are used with a
parallel kit (sold separately) that will allow generators to be
linked together to increase output.
NOTICE:
Do not disconnect cables while the generator is running.
The generator or the load may be damaged.
NOTE:
Read and understand the parallel kit’s instructions
prior to use. Kit is for usage with this unit only.
RECOIL STARTER
The recoil starter is used (along with the Easy Start dial) to
start the generator’s engine.
RESET BUTTON
The reset button is used to restore power if an overload
occurs. To restore power, remove the last electrical load
added, then press the reset button.
RETRACTABLE HANDLE
The generator is equipped with a retractable handle that can
be adjusted for storage and transportation.
USB PORTS
The two 5 Volt, 2.1 Amp USB-dedicated charging ports will
charge most USB-compatible devices.
PRODUCT SPECIFICATIONS
ENGINE
Engine Type
.............................
80cc Overhead Valve (OHV)
Spark Plug
................................
Torch E6RTC or equivalent
Lubricant Fill Volume
..........................
Approximately 12 oz
Fuel Volume
.................................................................
1.2
gal.
GENERATOR
Rated Voltage
.............................................
120V AC/5V DC
Rated Amps
...............................................
15A AC/2.1A DC
Rated Output*
.........................................................
1,800 W
Starting Watts
.........................................................
2,300 W
Rated Frequency
........................................................
60 Hz
*Rated output determined by PGMA Standard G300