Ryobi RYi2300BTA Operation Manual - Page 18

Operation, Maintenance - spark plug

Page 18 highlights

OPERATION To stop the engine in an emergency situation: n Place the Easy Start dial in the OFF/STORAGE position. WARNING: While operating and storing, keep at least 3 feet of clearance on all sides of this product, including overhead. Allow a minimum of 30 minutes of "cool down" time before storage. Heat created by muffler and exhaust gases could be hot enough to cause serious burns and/ or ignite combustible objects. PAIRING THE BLUETOOTH® GENERATOR See Figure 8. Installing the RYOBI GENCONTROL app on your Bluetooth® enabled iOS or Android device allows you to view and control many of the generator's functions from your device.  From the app store on your iOS or Android Bluetooth® enabled device, locate and install the RYOBI GENCONTROL™ app.  Open the app and follow the directions as shown in the GENControl app. NOTE: Make sure Bluetooth® is enabled on your device.  Start the generator. Push and hold the "Push and Hold to Pair" button below the LCD panel on the generator until the LCD panel displays "Pairing Mode."  The LCD screen on the generator and the app on your device will indicate a successful pairing. NOTE: If the generator and app do not pair, make sure that "Pairing Mode" is displayed during the pairing process and that Bluetooth® is enabled on your device.  Press the menu icon in the top left corner of the screen. This will show you the available features that can be controlled through the app. MOVING THE GENERATOR See Figure 9. n Place the Easy Start dial in the OFF/STORAGE position. In the OFF/STORAGE position, the fuel valve will be closed and prevent any gas flow. n Allow 30 minutes of "cool down" time before storing the machine. Make sure engine and exhaust of unit are cool. n Pull the retractable handle out or carry by the carry handles. n Facing the front of the generator, grasp the folding handle firmly with one hand. n Lift the generator toward you until it balances on the wheels. n Turn around and pull the unit along behind you to the desired location. n Lower the generator until it sits securely on a flat surface. MAINTENANCE Normal maintenance, replacement or repair of emission control devices and systems may be performed by any qualified repair establishment or individual with original or equivalent parts. Warranty and recall repairs must be performed by an authorized service center; please contact customer service for assistance. WARNING: NOTICE: Periodically inspect the entire product for damaged, missing, or loose parts such as screws, nuts, bolts, caps, etc. Tighten securely all fasteners and caps and do not operate this product until all missing or damaged parts are replaced. Please contact customer service or a qualifed service center for assistance. Before inspecting, cleaning or servicing the machine, shut off engine, wait for all moving parts to stop, and disconnect spark plug wire and move it away from spark plug. Allow 30 minutes of cool down time before performing any maintenance. Failure to follow these instructions can result in serious personal injury or property damage. WARNING: GENERAL MAINTENANCE Keep the generator in a clean and dry environment where it is not exposed to dust, dirt, moisture, or corrosive vapors. Do not allow the cooling air slots in the generator to become clogged with foreign material such as leaves, etc. Do not use a garden hose to clean the generator. Water entering the fuel system or other internal parts of the unit can cause problems that will decrease the life of the generator. To clean the unit: When servicing, use only recommended or equivalent replacement parts. Use of any other parts could create a hazard or cause product damage. n Use a soft bristle brush and/or vacuum cleaner to loosen and remove dirt and debris. n Clean air vents with low pressure air that does not exceed 25 psi. n Wipe the exterior surfaces of the generator with a damp cloth. 14 - English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

14 — English
OPERATION
To stop the engine in an emergency situation:
Place the Easy Start dial in the OFF/STORAGE
position.
WARNING:
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of “cool down” time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.
PAIRING THE BLUETOOTH
®
GENERATOR
See Figure 8.
Installing the RYOBI GENCONTROL app on your
Bluetooth
®
enabled iOS or Android device allows you to view and control
many of the generator’s functions from your device.
From the app store on your iOS or Android
Bluetooth
®
enabled device, locate and install the RYOBI
GENCONTROL™ app.
Open the app and follow the directions as shown in the
GENControl app.
NOTE:
Make sure
Bluetooth
®
is enabled on your device.
Start the generator. Push and hold the “Push and Hold to
Pair” button below the LCD panel on the generator until
the LCD panel displays “Pairing Mode.”
The LCD screen on the generator and the app on your
device will indicate a successful pairing.
NOTE:
If the generator and app do not pair, make sure
that “Pairing Mode” is displayed during the pairing process
and that
Bluetooth
®
is enabled on your device.
Press the menu icon in the top left corner of the screen.
This will show you the available features that can be
controlled through the app.
MOVING THE GENERATOR
See Figure 9.
Place the Easy Start dial in the OFF/STORAGE position. In
the OFF/STORAGE position, the fuel valve will be closed
and prevent any gas flow.
Allow 30 minutes of “cool down” time before storing the
machine. Make sure engine and exhaust of unit are cool.
Pull the retractable handle out or carry by the carry handles.
Facing the front of the generator, grasp the folding handle
firmly with one hand.
Lift the generator toward you until it balances on the
wheels.
Turn around and pull the unit along behind you to the
desired location.
Lower the generator until it sits securely on a flat surface.
MAINTENANCE
Normal maintenance, replacement or repair of emission con-
trol devices and systems may be performed by any qualified
repair establishment or individual with original or equivalent
parts. Warranty and recall repairs must be performed by an
authorized service center; please contact customer service
for assistance.
WARNING:
Before inspecting, cleaning or servicing the machine, shut
off engine, wait for all moving parts to stop, and disconnect
spark plug wire and move it away from spark plug. Allow
30 minutes of cool down time before performing any
maintenance. Failure to follow these instructions can result
in serious personal injury or property damage.
WARNING:
When servicing, use only recommended or equivalent
replacement parts. Use of any other parts could create
a hazard or cause product damage.
NOTICE:
Periodically inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts,
caps, etc. Tighten securely all fasteners and caps and
do not operate this product until all missing or damaged
parts are replaced. Please contact customer service or
a qualifed service center for assistance.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water
entering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
To clean the unit:
Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
Clean air vents with low pressure air that does not exceed
25 psi.
Wipe the exterior surfaces of the generator with a damp cloth.