Check code, Meaning, Solution, Clg Cg, Ducting requirements, C80 C8, C90 C9

Page 35 highlights

Installation Installation check codes Check code 0 Clg (Cg) C80 (C8) C90 (C9) Ct tC C1 dC 9C1 Meaning Vent condition is good. The vent is clogged. About 80 % of the vent is clogged. (This may decrease the drying performance.) Over 90 % of the vent is clogged. (This may lead to poor drying performance or cause malfunction) The internal temperature of the dryer is too low (below 32 °F (0 °C)) or too high (over 104 °F (40 °C)) and therefore vent blockage cannot be detected. Temperature sensor error Unit is detecting items inside the drum or there is an error on the dry sensor. Unit is detecting door is open Abnormal voltage detected Solution 1. Clean the lint filter. 2. Check your vent condition. (Refer to the "Ducting requirements" section) * You must take measures (such as cleaning) through expert personnel. Leave the dryer at room temperature (41~95 °F (5~35 °C)) for an hour and check again. Contact a service center. Remove items from the drum and check again. If the problem continues, contact a service center. Close the door properly and check again. If the problem continues, contact a service center. Check the power connection. (Refer to the "Connect the electrical wiring (for electric models)" section) If the problem continues, contact a service center. Untitled-4 35 English 35 2020-07-14 12:33:05

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

English
35
Installation
Installation check codes
Check code
Meaning
Solution
0
Vent condition is good.
Clg (Cg)
The vent is clogged.
1.
Clean the lint filter.
2.
Check your vent condition. (Refer
to the “
Ducting requirements
section)
* You must take measures (such as
cleaning) through expert personnel.
C80 (C8)
About 80 % of the vent is clogged.
(This may decrease the drying
performance.)
C90 (C9)
Over 90 % of the vent is clogged.
(This may lead to poor drying
performance or cause malfunction)
Ct
The internal temperature of the
dryer is too low (below 32 °F (0 °C))
or too high (over 104 °F (40 °C)) and
therefore vent blockage cannot be
detected.
Leave the dryer at room
temperature (41~95 °F (5~35 °C))
for an hour and check again.
tC
Temperature sensor error
Contact a service center.
C1
Unit is detecting items inside the
drum or there is an error on the dry
sensor.
Remove items from the drum and
check again.
If the problem continues, contact a
service center.
dC
Unit is detecting door is open
Close the door properly and check
again.
If the problem continues, contact a
service center.
9C1
Abnormal voltage detected
Check the power connection. (Refer
to the “
Connect the electrical wiring
(for electric models)
” section)
If the problem continues, contact a
service center.