Samsung NA30N6555TG/AA Installation Guide - Page 24

Converting the pressure regulator, Screwdrivers: Phillips

Page 24 highlights

Installation instructions Required tools Adjustable wrench 1/2" open-end wrench Screwdrivers: Phillips Converting the pressure regulator NOTE If you are using LP gas to fuel the cooktop, the following steps and conversions must be made before the flames can be adjusted. 1. Using your fingers, turn the cap. And carefully look at the spring retainer to locate the NAT or LP position. LP Cap NAT Gasket Small flat-bladed precision screwdriver Nut drivers: 9/32" or 7 mm To convert your for use with LP gas, perform the following steps and procedures: 1. Disconnect electrical power to the cooktop. Unplug the cooktop power cord, trip the circuit breaker, or remove the fuse from the fuse box. 2. Shut off the gas supply to the cooktop. Close the manual shut-off valve to the cooktop. NAT LP NAT NAT. Position LP NAT Spring Retainer L.P./Propane LP Position Pressure Regulator 2. Turn the spring retainer over by rotating it 90 deg., pull it from the cap, turn the spring retainer over so that LP is showing, insert it back into the cap, and then rotate it 90 deg. Into position. 3. Screw the cap back onto the regulator and tighten. Installation instructions 24 English Install_NA30N6555TG_DG68-01091A-02_EN+MES+CFR.indb 24 10/24/2018 4:29:27 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

24 English
Installation instructions
Installation instructions
Required tools
Adjustable wrench
1
/
2
” open-end wrench
Screwdrivers: Phillips
Small flat-bladed
precision screwdriver
Nut drivers:
9
/
32
” or 7
mm
To convert your for use with LP gas, perform the following steps and procedures:
1.
Disconnect electrical power to the cooktop.
Unplug the cooktop power cord, trip
the circuit breaker, or remove the fuse from the fuse box.
2.
Shut off the gas supply to the cooktop.
Close the manual shut-off valve to the
cooktop.
Converting the pressure regulator
NOTE
If you are using LP gas to fuel the cooktop, the following steps and conversions
must be made before the flames can be adjusted.
1.
Using your fingers, turn the cap. And carefully look at the spring retainer to
locate the NAT or LP position.
LP
LP
LP
LP
NAT
NAT
NAT
NAT. Position
L.P./Propane
Position
Pressure Regulator
Spring
Retainer
NAT
Cap
Gasket
2.
Turn the spring retainer over by rotating it 90 deg., pull it from the cap, turn the
spring retainer over so that LP is showing, insert it back into the cap, and then
rotate it 90 deg. Into position.
3.
Screw the cap back onto the regulator and tighten.