Sanyo CE42LH2WP Owner's Manual - Page 11

Installation Mode

Page 11 highlights

GB INSTALLATION MODE GB Installation Mode Installation Mode G2.02 0000 On program Tuner Menu Max Volume Winter mode RC inhibition Child Lock Address Baud rate Panel protection AV Auto shut off Network Standby On Timer Function LED light setting DCR Network initial Temperature Error IP Address Subnet Gateway DNS Off Off 63 Off Off Off 0 19200 Off Off On Off Off Off >>> 0 000000000000 000000000000 000000000000 000000000000 Select Adjust MENU Exit This LCD monitor allows you to set up the following: SETTING PROCEDURE 1. Press and hold the GREEN button on the remote control for 5 seconds. (Installation Mode will appear) 2. Use the  or  button to highlight each option, use the  or  button to adjust each option. Press the MENU button to exit the mode. N On Program Select ON program using the  or  button, select the start up position using the  or  buttons. 2II$95*%$9$93&'9,RU1HWZRUN N Max Volume Select Max volume using the  or  button, use the  or  buttons to set the maximum volume required. N Winter mode This Function can be activated when the LCD monitor is used durLQJFROGWHPSHUDWXUHFRQGLWLRQVDSSUR[LPDWHO RUEHORZWR maintain picture performance. Using the  or  button select winter mode, once highlighted you can select ON or OFF by pressing the  or  button. IMPORTANT: The AC cord should not be disconnected during the operation of Winter mode function. When in winter mode, power consumption is higher than normal standby consumption. This is entirely due to the operation of heating circuitry. We strongly recommend to turn off Winter mode when the DPELHQWWHPSHUDWXUHLVDERYHÛ)Û& N RC inhibition You can prevent unwanted remote control operation by selecting RC Inhibition. Select using the  or  button. Press the  or  button to select On or Off. To re-instate RC operation press and hold the green button on the remote control and select RC inhibition OFF. N Child Lock You can prevent unwanted operation of the LCD monitor via the buttons on the rear of the monitor. Select using the  or  button. Press the  button to select 2QRU2))7KH³&KLOG/RFN´26'ZLOODSSHDULIEXWWRQVDUHSUHVVHG ZKHQFKLOGORFNLV2Q  6 WDQGE\RSHUDWHVQRUPDOO\ZKHQFKLOGORFNLVVHW³2Q´ N Address Set the address for the LCD monitor (0 ~ 999). LSetting the monitor address in RS232 mode (DFKPRQLWRUFDQKDYHDVSHFL¿F$GGUHVVZKLFKKHOSVFRPPDQG that monitor individually and will not effect to other monitors connected to a controlling PC Address format command. The addressing format command is used for operating multiple monitor sets from a single PC via the RS232C command line. N Baud rate Select Baud rate using the  or  button. To set transmission speed RS232 or LD-NET communication for 19200 or 9600 Baud rate by pressing the  or  button. N Panel protection 7RSUHYHQWLPDJHVWLFNLQJZKLFKPD\RFFXUVKRZLQJVWLOOSLFWXUHIRUD long time, select "Panel Protect" using the  or  button, once highlighted you can select ON or OFF by pressing the  or  button. N AV Auto shut off With no picture input signal to AV1, RGB, AV2(YPbPr), AV3, DVI, 1HWZRUNVHWWXUQVRIIDXWRPDWLFDOO\6HOHFW³$9$XWR6KXW2II´XVLQJ the  or  button, once highlighted you can select On or Off by pressing the  or  button. N Network Standby

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33

11
INSTALLATION MODE
Installation Mode
Installation Mode
On program
Tuner Menu
Max Volume
Winter mode
RC inhibition
Child Lock
Address
Baud rate
Panel protection
AV Auto shut off
Network Standby
On Timer Function
LED light setting
DCR
Network initial
Temperature Error
IP Address
Subnet
Gateway
DNS
Off
Off
63
Off
Off
Off
0
19200
Off
Off
On
Off
Off
Off
>>>
0
000000000000
000000000000
000000000000
000000000000
G2.02 0000
Select
Ad
j
ust
MENU
Exit
This LCD monitor allows you to set up the following:
SETTING PROCEDURE
1.
Press and hold the
GREEN button
on the remote control for 5
seconds. (Installation Mode will appear)
2.
Use the
or
button
to highlight each option, use the
or
button
to adjust each option. Press the
MENU button
to exit
the mode.
On Program
Select ON program using the
or
button
, select the start up
position using the
or
buttons
.
Max Volume
Select Max volume using the
or
button
, use the
or
buttons
to set the maximum volume required.
Winter mode
This Function can be activated when the LCD monitor is used dur-
maintain picture performance.
Using the
or
button
select winter mode, once highlighted you
can select ON or OFF by pressing the
or
button
.
IMPORTANT: The AC cord should not be disconnected during the
operation of Winter mode function.
When in winter mode, power consumption is higher than normal
standby consumption. This is entirely due to the operation of heating
circuitry. We strongly recommend to turn off Winter mode when the
RC inhibition
You can prevent unwanted remote control operation by selecting RC
Inhibition.
Select using the
or
button
. Press the
or
button
to
select On or Off.
To re-instate RC operation press and hold the green button on the
remote control and select RC inhibition OFF.
Child Lock
You can prevent unwanted operation of the LCD monitor via the
buttons on the rear of the monitor.
Select using the
or
button
. Press the
button
to select
Address
Set the address for the LCD monitor (0 ~ 999).
Setting the monitor address in RS232 mode
that monitor individually and will not effect to other monitors con-
nected to a controlling PC Address format command.
The addressing format command is used for operating multiple
monitor sets from a single PC via the RS232C command line.
Baud rate
Select Baud rate using the
or
button
. To set transmission
speed RS232 or LD-NET communication for 19200 or 9600 Baud rate
by pressing the
or
button
.
Panel protection
long time, select “Panel Protect” using the
or
button
, once
highlighted you can select ON or OFF by pressing the
or
button
.
AV Auto shut off
With no picture input signal to AV1, RGB, AV2(YPbPr), AV3, DVI,
the
or
button
, once highlighted you can select On or Off by
pressing the
or
button
.
Network Standby
in Installation mode, both RS232C and LD-NET do not functional. To
On Timer Function
You can save power consumption selecting “Off” at On Timer function
in Installation mode. On Timer in Time menu does not functional. To
LED Light setting
Select LED Light setting using the
or
button
, once highlight-
ed you can select On or Off by pressing the
or
button
.
DCR
The picture contrast improved while DCR is ON. Select DCR using
the
or
button
, once highlighted you can select On or Off by
pressing the
or
button
.
Network Initial
This function automatically installs the IP Address, Subnet, Gateway
and DNS information.
Temperature Error
The recorded number of abnormal temperature is occurred is indi-
cated here.
IP Address/Subnet/Gateway/DNS
These 4 items display the LD-Net information. If LD-NET is NOT con-
nected, all the items would be displayed as “000000000000”.
Disconnecting the mains supply before exiting Installation Mode will
cancel the following features On program, RC inhibition, Address
and Baud Rate.
GB
GB