Sanyo CE52LH1R Owner's Manual - Page 10
Tion Mode
UPC - 086483069611
View all Sanyo CE52LH1R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
GB INSTALLATION MODE GB Installation Mode Installation Mode VER -.-- I LED Light setting Select LED Light setting using the 5 or 6 button, once highlighted you can select On or Off by pressing the 1 or 2 button. I DCR Select DCR using the 5 or 6 button, once highlighted you can select On or Off by pressing the 1 or 2 button. I Network Initial This function automatically installs the IP Address, Subnet, Gateway and DNS information. Network Initial >>> Temperature Error I Temperature Error This function can record times for abnormal temperture. I IP Address / Subnet / Gateway / DNS These 4 items display the LD-Net information. If LD-NET is NOT connected, all the items would be displayed as "000000000000". This LCD monitor allows you to set up the following: i Disconnecting the mains supply before exiting Installation Mode will cancel the following features On program, RC inhibition, Address and Baud Rate. SETTING PROCEDURE 1 . Press and hold the GREEN button on the remote control for 5 seconds. (Installation Mode will appear) 2. Use the 5 or 6 button to highlight each option, use the 1 or 2 button to adjust each option. Press the MENU button to exit the mode. I On Program Select ON program using the 5 or 6 button, select the start up position using the 1 or 2 buttons. (Off/ AV1/ RGB/ AV2/ AV3/ PC/ DVI or Network) I Max Volume Select Max volume using the 5 or 6 button, use the 1 or 2 buttons to set the maximum volume required. I Winter mode This Function can be activated when the LCD monitor is used during cold temperature conditions, approximately 38˚F/ 4˚C or below to maintain picture performance. Using the 5 or 6 button select winter mode, once highlighted you can select ON or OFF by pressing the 1 or 2 button. IMPORTANT: The AC cord should not be disconnected during the operation of Winter mode function. When in winter mode, power consumption is higher than normal standby consumption. This is entirely due to the operation of heating circuitry. We strongly recommend to turn off Winter mode when the ambient temperature is above 38˚F/ 4˚C. I RC inhibition You can prevent unwanted remote control operation by selecting RC Inhibition. Select using the 5 or 6 button. Press the 1 or 2 button to select On or Off. To re-instate RC operation press and hold the green button on the remote control and select RC inhibition OFF. I Child Lock You can prevent unwanted operation of the LCD monitor via the buttons on the rear of the monitor. Select using the 5 or 6 button. Press the 1 button to select On or OFF. The 'Child Lock' OSD will appear if buttons are pressed when child lock is On. i Standby operates normally when childlock is set "On". I Address Set the address for the LCD monitor (0 - 999). I Baud rate Select Baud rate using the 5 or 6 button. To set transmission speed RS232 or LD-NET communication for 19200 or 9600 Baud rate by pressing the 1 or 2 button. I Panel Protect Select Panel Protect using the 5 or 6 button, once highlighted you can select ON or OFF by pressing the 1 or 2 button. I AV Auto shut off Select AV Auto Shut Off using the 5 or 6 button, once highlighted you can select On or Off by pressing the 1 or 2 button. 10