Sanyo CE52LH1R Owner's Manual - Page 17

Error code Table

Page 17 highlights

RS232C Command Tables Time Read Command Table Status read command CR PANELH CR MONH Item Status of accumulated lifetime of panel. The same as CR_LAMPH Command Status of accumulated lifetime of monitor The same as CR_PROJH Command Sound control Read Command Table Status read command CR VOLUME CR MUTE Status of volume value. Status of MUTE. Item Setting Read Command Table Status read command CR LANG CR P-MANE CR TILE CR TILE-HSETS CR TILE-VSETS CR TILE-HLOCAT CR TILE-VLOCAT CR TILE-BZLHADJ CR TILE-BZLVADJ CR ONPROG CR WINTERMODE CR PANELPROTECT CR LEDLIGHT CR AVAUTOSHUT CR CHILDLOCK CR RCINHIBITION Item Status of Language selection. Status of Power management setting Status of Tile mode ON/OFF setting Status of Tile mode, the number of Horizontal array. Status of Tile mode, the number of Vertical array. Status of Tile mode, the number of Horizontal allocation. Status of Tile mode the number of Horizontal allocation. Status of Tile mode, the width of bezel Horizontal Status of Tile mode, the width of bezel (Vertical) Status of On Program information/ Status of Winter mode Information. Statuses of Panel protect Information. Status of LED light Information. Status of AV auto shut OFF Information. Statuses of Child lock Information. Status of RC Inhibit Information. Other Read Command Table Status read command Item CR STATUS CR SIGNAL CR FREEZE CR FANLOCK CR TEMP Status of the operation of the monitor. Status of with or without signal. Status of Freeze setting. Statuses of fun lock error. Status of current temperature value. UK5 Read Command Table (Basic Command) Command Item Note CR0 CR1 Power Input Mode On, Standby, power error, AV1, AV2, ..., DVI, PC CR WIDE CR PICTURE CR SIGNAL CR CHILD CR PSAVE CRTM Wide mode Picture mode Signal existence Child lock Power save Panel usage time Auto, Normal, Full, ... Dynamic, Standard, ... Signal / No signal On / Off On / Off CR RMC RC inhibition On / Off CR MDL Model number 52LH1 Error code Table Error code Receiving the data that cannot be decoded The wrong indication of parameter Wrong figured number, or wrong word is included. Normal receiving no error If the command of out of range is directly entered valuable parameter. No matching with Hardware (Command for optional function which is not equipped.) If the command of "Out of range" is entered by inclement or decrements by numeric value. While capturing the picture, no execution. Wait and transmit command again. While PIN code is in operation, no execution. Wait and transmit command again. The errors not including above. 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

43
RS232C Command T
RS232C Command T
ables
ables
Time Read Command Table
Status read command
I
tem
CR PANELH
Status of accumulated lifetime of panel.
The same as CR_LAMPH Command
CR MONH
Status of accumulated lifetime of monitor
The same as CR_PROJH Command
Sound control Read Command Table
Status read command
I
tem
CR VOLUME
Status of volume value.
CR MUTE
Status of MUTE.
Setting Read Command Table
Status read command
I
tem
CR LANG
Status of Language selection.
CR P-MANE
Status of Power management setting
CR T
I
LE
Status of Tile mode ON/OFF setting
CR T
I
LE-HSETS
Status of Tile mode, the number of Horizontal array.
CR T
I
LE-VSETS
Status of Tile mode, the number of Vertical array.
CR T
I
LE-HLOCAT
Status of Tile mode, the number of Horizontal allocation.
CR T
I
LE-VLOCAT
Status of Tile mode the number of Horizontal allocation.
CR T
I
LE-BZLHADJ
Status of Tile mode, the width of bezel
Horizontal
CR T
I
LE-BZLVADJ
Status of Tile mode, the width of bezel (Vertical)
CR ONPROG
Status of On Program information/
CR W
I
NTERMODE
Status of Winter mode
I
nformation.
CR PANELPROTECT
Statuses of Panel protect
I
nformation.
CR LEDL
I
GHT
Status of LED light
I
nformation.
CR AVAUTOSHUT
Status of AV auto shut OFF
I
nformation.
CR CH
I
LDLOCK
Statuses of Child lock
I
nformation.
CR RC
I
NH
I
B
I
T
I
ON
Status of RC
I
nhibit
I
nformation.
Other Read Command Table
Status read command
I
tem
CR STATUS
Status of the operation of the monitor.
CR S
I
GNAL
Status of with or without signal.
CR FREEZE
Status of Freeze setting.
CR FANLOCK
Statuses of fun lock error.
CR TEMP
Status of current temperature value.
UK5 Read Command Table (Basic Command)
Command
I
tem
Note
CR0
Power
On, Standby, power error,
CR1
I
nput Mode
AV1, AV2, ..., DV
I
, PC
CR W
I
DE
Wide mode
Auto, Normal, Full, …
CR P
I
CTURE
Picture mode
Dynamic, Standard, …
CR S
I
GNAL
Signal existence
Signal / No signal
CR CH
I
LD
Child lock
On / Off
CR PSAVE
Power save
On / Off
CRTM
Panel usage time
CR RMC
RC inhibition
On / Off
CR MDL
Model number
52LH1
Error code Table
Error code
Receiving the data that cannot be decoded
The wrong indication of parameter
Wrong figured number, or wrong word is included.
Normal receiving
no error
If the command of out of range is directly entered
valuable parameter.
No matching with Hardware
(Command for optional function which is not equipped.)
If the command of “Out of range” is entered by
inclement or decrements by numeric value.
While capturing the picture, no execution. Wait and
transmit command again.
While PIN code is in operation, no execution.
Wait and transmit command again.
The errors not including above.